OV-II Maintenance, Troubleshooting and Service Manual
SYMPTOM
No image appears as
stawheel turns
The bottle is inspected
and detected but not
rejected.
2-26
3. Verify that the system is being triggered for inspection by noting
whether the PERIOD TOTALS counter (on any of the STATUS
screens listed in Step #3) increments when the starwheel is rotated.
If the bottle counter is not counting, then the problem is not
specifically due to the rejector or the sensitivity of the inspection
zones. It is possible that the starwheel encoder (located underneath
the starwheel motor) has been disconnected and cannot detect the
starwheel turning.
4. If the problem is not resolved after trying Steps #1 through #4, use the
following table to look for possible causes and solutions.
CHECK
Starwheel encoder.
One or more of the reject settings
are incorrect.
SOLUTION
Bad encoder, power or wiring.
Repair as required.
Go to the CONTAINER SETUP >
TRIGGER SETUP screen to verify
the current bottle type parameters.
Industrial Dynamics Company, Ltd. © Form 42600 (10/03)