Chapter 1: Maintenance; Periodic Maintenance Overview; Periodic Maintenance Procedure; Daily Maintenance - Filtec OV-II Maintenance, Troubleshooting And Service Manual

Table of Contents

Advertisement

PERIODIC MAINTENANCE OVERVIEW

PERIODIC MAINTENANCE PROCEDURE

NOTE

Daily Maintenance

ITEM
Diffuser Glass
Water Drip System
Inspection Head Lens and Optical
Window Glass
Starwheel Suction Cups
Industrial Dynamics Company, Ltd. © Form 42600 (10/03)
This chapter provides guidelines for periodic maintenance on the
Omnivision All Surface Empty Bottle Inspector (ASEBI), including the
optional Outer Sidewall (OSW) Inspection System.
The Omnivision system is designed to operate without requiring intensive
amounts of maintenance. Industrial Dynamics Company (IDC) strongly
recommends that the maintenance procedures contained in this chapter be
followed as closely as possible. Consistent and timely maintenance of the
Omnivision system ensures long-term equipment reliability.
This section provides the daily, weekly and monthly routine maintenance
for the Omnivision system.
The camera, mirrors, servos, and mirror heater(s) inside the optional
OSW system are enclosed and sealed off. They are designed to
operate on a long-term basis without regular maintenance being
required. None of the OSW system components require lubrication.
Do not open the OSW system enclosure unless absolutely necessary.
Opening the OSW enclosure allows dirt, product, water, and other
fluids/gases to contaminate the optical components.
Clean thoroughly top and bottom. Clean with a NONCAUSTIC,
NONABRASIVE commercially available glass cleaner (such as
Windex). Maintain cleanliness by adjusting the diffuser glass
wiper brush and water drip system. Dirty diffuser glass causes
"false rejects."
Check and adjust for slow drip.
Clean inspection head lens and external cover glass surface with
lens tissue or soft cloth. Dirty window causes loss of light to
Inspection Head systems.
DO NOT CLEAN LENSES OR GLASS WITH ANY
CAUSTIC OR ABRASIVE MATERIALS.
Check for splits, cuts, or other damage. Replace if worn or
detective. Defects cause loss of vacuum and rejection of good
bottles.
Chapter 1: Periodic Maintenance
DAILY MAINTENANCE
1-1