Advertisement

Quick Links

MANN+HUMMEL
IQORON 7, 10, 12, 14
Installation and Maintenance Manual
Version 0709

Advertisement

Table of Contents
loading

Summary of Contents for MANN+HUMMEL IQORON 7

  • Page 1 MANN+HUMMEL IQORON 7, 10, 12, 14 Installation and Maintenance Manual Version 0709...
  • Page 2: Table Of Contents

    Installing the main filter element ..10 Maintenance of the cyclone block .... 10 The maintenance indicator and secondary Storing Filter Elements ........10 filter element are optionally available and, Troubleshooting ..........11 Disposing of Parts .......... 12 MANN+HUMMEL Industrial Filters...
  • Page 3: Safety

    The IQORON has been exclusively designed minimal assembly and disassembly forces, for the mechanical filtration of air. An other defined contact forces for the seals, use above or beyond this, such as filtering MANN+HUMMEL Industrial Filters...
  • Page 4 Fig. 1 IQORON, size 7 Pos. Name Pos. Name Housing Main filter element Connection for maintenance indicator/switch Cyclone block Clean air connection Allen screw Wire clamp fastener Dust discharge connection Secondary element MANN+HUMMEL Industrial Filters...
  • Page 5 IQORON size 10 (sizes 12 and 14 are comparable) Pos. Name Pos. Name Connection for maintenance indicator/switch Main filter element Clean air connection Cyclone block Wire clamp fastener Allen screw Secondary element Dust discharge connection Filter frame with locking bar Housing MANN+HUMMEL Industrial Filters...
  • Page 6: Installation

    (M10x1, Pos. 7) or (Pos. 5) when the engine is seal the connection with a cap nut. operating at a partial load and at least mbar vacuum when operating at full-load. MANN+HUMMEL Industrial Filters...
  • Page 7: Maintenance

    If leak tests must be carried out using higher pressure or vacuum levels, the maintenance indicator/switch must be disassembled for the period of the test and the connection on the filter sealed. Reset the maintenance indicator after the test by actuating the Reset button. MANN+HUMMEL Industrial Filters...
  • Page 8: Maintenance Plan

    Remove the frame (Pos. 11) together with the main filter element (Pos. 2). Remove the main filter element from the frame and dispose of it according to the local regulations. Fig. 5 Cleaning the IQORON main filter element (Fig. illustrates size 7) MANN+HUMMEL Industrial Filters...
  • Page 9: Installing The Main Filter Element

    6.2.3 Installing the main filter element frame towards the clean side as far as possible. Only use original MANN+HUMMEL Do not press on the paper bellows! elements! IQORON series 7: Install the main filter element in the housing.
  • Page 10: Installing The Main Filter Element

    Protect filter elements in storage from exposure to dust, moisture and damage. It is preferable to keep them stored in their original packaging. It is practical to keep at least one spare element in stock for each filter element used. MANN+HUMMEL Industrial Filters...
  • Page 11: Troubleshooting

    (refer to Section 6) Incorrect main and/or secondary Remove dust thoroughly, install original element installed MANN+HUMMEL filter element Check maintenance indicator/switch (refer to Section 6, Footnote: Maintenance indicator/switch defect Maintenance Plan), replace as...
  • Page 12: Disposing Of Parts

    PA 6-GF30 Plastics recycling center PA 6-GF30 Housing with wire clamp fasteners Dispose of according to local Steel and threaded sockets regulations Brass Foam filter PA 6 Plastics recycling center Screw and washer Steel, galvanized Metal recycling center MANN+HUMMEL Industrial Filters...
  • Page 13 MANN+HUMMEL IQORON Notes MANN+HUMMEL GMBH, Geschäftsbereich Industriefilter 67346 Speyer, Germany, Telephone +49 (62 32) 53-80, Fax +49 (62 32) 53-88 99 E-mail: if.info@mann-hummel.com, Internet: www.mann-hummel.com MANN+HUMMEL Industrial Filters...

This manual is also suitable for:

Iqoron 10Iqoron 14Iqoron 12Iqoron-v 7

Table of Contents