I TO SERVICE PERSONNEL
1. Critical Components Information
Components having special characteristics are marked s
and must be replaced with parts having specifications equal
to those originally installed.
2. Leakage Current Measurement (For 120V Models Only)
When service has been completed, it is imperative to verify
that all exposed conductive surfaces are properly insulated
from supply circuits.
Meter impedance should be equivalent to 1500 ohms
G
shunted by 0.15µF.
WARNING: CHEMICAL CONTENT NOTICE!
The solder used in the manufacturing process except soldering of the P.C.B. ass'y contains LEAD. In addition, other
electrical/electronic and /or plastic (where applicable) components may also contain traces of chemicals found by the
California Health and Welfare Agency (and possibly other entities) to cause cancer and/or birth defects or other reproductive
harm.
DO NOT PLACE SOLDER, ELECTRICAL/ELECTRONIC OR PLASTIC COMPONENTS IN YOUR MOUTH FOR ANY REA-
SON WHATSOEVER!
Avoid prolonged, unprotected contact between solder and your skin! When soldering, do not inhale solder fumes or expose
eyes to solder/flux vapor!
If you come in contact with solder or components located inside the enclosure of this product, wash your hands before
handling food.
About Lead Free Solder
The P.C.B.s installed in this unit are soldered using the following solder.
MAIN P.C.B
OPERATION P.C.B
Among some types of lead free solder currently available, it is recommended to use one of the following types for the repair
work.
• Sn + Ag + Cu (tin + silver + copper)
• Sn + Cu (tin + copper)
• Sn + Zn + Bi (tin + zinc + bismuth)
Caution:
1. As the melting point temperature of the lead free solder is about 30°C to 40°C (50°F to 70°F) higher than that of the lead
solder, be sure to use a soldering iron suitable to each solder.
2. If lead solder must be used, be sure to remove lead free solder from each terminal section of the parts to be replaced and
from the area around it completely before soldering, or make sure that the lead free solder and lead solder melt together
fully.
2
SIDE A
-
-
REFLOW
Side A
SMT
Solder Dip
FLOW
Side B
MI
WALL
EQUIPMENT
OUTLET
UNDER TEST
INSULATING
TABLE
G
Leakage current must not exceed 0.5mA.
G
Be sure to test for leakage with the AC plug in both polarities.