Appendix
9.
Appendix
9.1.
Help with problems
Problem
Cause
Teach-in failed
Batteries
inserted
incorrectly
Radio
connection
failure
HC60NG does
HC60NG
not react to set
and HCW
point changes
80 not
on HCW 80
bound
After teach-in
Teach-in
red LED is on
procedure
and green LED
incorrect/
is flashing once
incomplete
every 3 sec
Position of
HCW 80
incorrect
Red LED of the
Communi-
HC60NG is on
cation loss
RF signal
blocked
Batteries of
HCW 80
exhausted
9.2.
Technical data
Batteries
1.5 V, type LR06, AA
Frequency
868.3 MHz (transmitter)
Operating temperature
0 °C to 50 °C
Storage temperature
–20 °C to 70 °C
Humidity
5 % to 90 % relative humidity
9.3.
Device and function definition in
accordance with EN 60730-1
•
Purpose of the device is temperature controlling
•
Device fulfils Protection class 1, EN 60730-1
•
Independently installable electronic control system
with fixed installation
•
Type of action is Type 1.8
•
Temperature of ball thrust hardness test for
housing components 75 °C and for live parts such
as, for example, terminals 125 °C
•
EMC emitted interference test at 230 V∼, 50 HZ
maximum
•
Pollution severity is 2
•
Rated voltage is 4000 V (corresponding to
Overvoltage category III)
•
Software class is A
8
Remedy
Insert the batteries
►
correctly.
Eliminate interference
►
sources (metal, wireless
devices).
Correct installation site.
►
Repeat the teach-in.
►
Reset HC60NG.
►
Follow the teach-in
►
procedure as described
in section "3.3".
Repeat the teach-in.
►
Repeat the teach-in
►
keeping approx. 1 m
distance between HCW
HC60NG.
80 and
Relocate the HCW 80
►
(see section "3.2").
Replace batteries in
►
HCW 80
(see section "8").