7.3.
Connecting the fixture to the mains
Warning! Make sure mains power is switched off.
Warning! Always install the lamp before connecting the fixture to the mains.
Warning! Ensure the cord is not coiled and does not touch any hot surfaces.
Warning! Connect the cables according to local rules, safety regulations and
electrical code.
Warning! Ensure external switching gear can cope with the inrush current of the
fixture (see paragraph 3.2). Always use a double pole contactor suitable for
switching a capacitive load. Never use household timers to switch the fixture!
Note: A power cord is not included in the package.
If not done already, remove the top part of Wieland RST20i3 female connector
from the bottom part (5).
Pull the mains cable through the bottom part (6).
Strip the wiring (7).
The insulation strip length is 8 mm / 0.31" and the dismantling
length is 32 mm / 1.26".
Connect the wiring to the top part connections (8).
Cable description:
Wire
Blue / White
Brown / Black
Green+Yellow
Slide the top part into the bottom part and tighten the gland nut (9).
Note: When the parts connect correctly, you will hear a 'CLICK' sound.
Plug the Wieland RST20i3 female connection onto the Wieland RST20i3 male
connection on the fixture (10).
Switch on mains power.
Warning! Do not connect or disconnect the Wieland RST20i3 plug under load.
1
1
8.
277V/347V
400V
Neutral (N)
Phase (N)
Phase (L)
Phase (L)
Ground (
)
Ground (