4. Position Linear Convector Baseboard, pushing cable back into wall
(or conduit), run screws through pre-selected mounting holes and
spacers (if applicable), using appropriate wall anchors, if necessary.
!
NOTE: Screw should be backed off 1/2 turn from snug position
to allow free expansion and contraction of housing and to ensure
quiet operation.
5. Replace covers on unit.
!
NOTE: Install the center cover first, by installing the top first,
then the bottom.
WIRING MULTIPLE LINEAR CONVECTOR BASEBOARDS
TOGETHER
Linear Convector Baseboards can be wired in together in parallel to
be controlled by a single thermostat. When units are wired in together
ensure that ground continuity is maintained between the units.
Operation
1. This Linear Convector Baseboard must be properly installed
before it is used.
2. Prior to energization remove all construction dirt (plaster, sawdust,
etc.) from interior and exterior of Linear Convector Baseboard.
Dimplex Linear Convector Baseboards are designed and tested
for safe and trouble-free operation. All Dimplex Linear Convector
Baseboards are protected against overheating by a built-in thermal
cutout. Free airflow throughout the Linear Convector Baseboard is
extremely important for the most efficient operation of the Linear
Convector Baseboard. Restricted airflow may cause the thermal
overload protector to cycle the Linear Convector Baseboard "ON and
OFF". A cycling Linear Convector Baseboard will not supply sufficient
heat to the room.
CAUTION: Avoid direct contact of paper, fabric, or furniture with
Linear Convector Baseboard, to prevent a possible fire.
Maintenance
CAUTION: Before removing the front cover for cleaning, make
certain the power has been turned off at the circuit breaker panel,
to prevent electric shock.
CAUTION: To avoid burns, allow adequate time for the element
INSTRUCTIONS IMPORTANTES
Lorsqu'un appareil électrique est utilisé, il est important de toujours
prendre des précautions de base pour réduire les risques d'incendie,
de chocs électriques et de blessures, y compris les suivantes :
1. Lire toutes les instructions avant d'utiliser le Plinthe-convecteur
linéaire.
2. Les plinthe-convecteurs linéaires et les contrôles doivent être
installés par un entrepreneur qualifié. Les procédures et les
connexions du câblage doivent être conformes au Code national
de l'électricité (CEC et NEC) et aux codes locaux.
3. Toutes les appareils de chauffage contiennent des pièces qui
chauffent et produisent un arc électrique ou des étincelles.Ne
pas faire fonctionner l'appareil dans des endroits où de l'essence,
de la peinture et autres produits inflammables sont utilisés ou
entreposés.
4. Le Plinthe-convecteur linéaire devient chaud lorsqu'il est en
marche. Pour éviter les brûlures, ne pas toucher les surfaces
chaudes. Tenir le Plinthe-convecteur linéaire éloigné des
matériaux combustibles comme : meubles, oreillers, literie,
papier, vêtements et rideaux.
5. Pour éviter un incendie, ne pas obstruer les entrées ou la sortie
d'air d'aucune façon. Ne pas utiliser l'appareil sur des surfaces
instables, comme un lit, où les ouvertures risquent d'être
obstruées.
6. Ne pas introduire ou permettre l'introduction de corps étrangers
dans la prise d'air de ventilation ou la bouche de sortie d'air,
car cela peut occasionner des chocs électriques, provoquer un
incendie ou endommager le Plinthe-convecteur linéaire.
2
and body casing to cool before attempting to work on the Linear
Convector Baseboard.
The LC series contain no moving parts. Since the appliance contains
no moving parts little maintenance is required beyond vacuum
cleaning. It is however essential that the Linear Convector Baseboard
is not operated with an accumulation of dust or dirt on the element,
as this can cause a build up of heat and eventual damage. For this
reason the Linear Convector Baseboard must be inspected regularly,
depending upon conditions and at least at yearly intervals. Once
cleaning is complete replace the front cover and restore power.
!
NOTE: The user can perform cleaning ONLY. All other servicing
should be performed by qualified service personnel.
Warranty
The Manufacturer warrants the Linear Convector Baseboard and components
of the enclosed product against any defect in material or workmanship for a
period of one year from the date of purchase, with the exception of the elements
which are warranted to be free from defect in material and workmanship for ten
years. In full satisfaction of any claims under this Warranty the Manufacturer
will repair or replace without charge, in its factory or in the field as it alone may
decide, any parts which in its opinion are defective.
The Manufacturer shall not be responsible for any transportation or shipping
costs in relation to such repair or replacement except as specifically assumed
by it. Misuse of this product or repairs by persons other than the Manufacturer's
authorized personnel without the Manufacturer's written approval, will void
this Warranty.
This Warranty is in lieu of all other warranties or conditions whether expressed
or implied including but not limited to those of merchantability or fitness for
purpose and shall constitute the sole remedy of the Purchaser and the sole
liability of the Manufacturer in respect of the sale of the product, whether
in the nature of breach or breach of fundamental term, or of negligence or
otherwise.
The Manufacturer shall not be liable for any special, indirect or consequential
damages or for any damages resulting from removal or replacement of a Linear
Convector Baseboard subject to warranty claim without the Manufacturer's
authorization.
This Warranty is transferable by the original consumer purchaser of the
product. Any claims under this Warranty must be submitted in writing to
the Service Manager, Dimplex North America Ltd., 1367 Industrial Rd.,
Cambridge, Ontario N3H 4W3, Canada.
Plinthe-convecteur linéaire
Série LC
7. Ne pas installer ces plinthe-convecteurs linéaires contre des
surfaces en fibres de cellulose à faible densité, contre ou sous
des revêtements muraux en vinyle.
8. Ne pas placer ces plinthe-convecteurs linéaires en-dessous de
prises de courant.
9. Vérifier la tension indiquée sur la plaque signalétique du Plinthe-
convecteur linéaire pour veiller à ce que la tension soit identique
à celle de la source d'alimentation. (La plaque signalétique est
située sous le côté droit de l'élément chauffant.)
10. HAUTES TEMPÉRATURES: Tenir les cordons électriques, les
meubles, les tentures ou autres obstructions éloignés du Plinthe-
convecteur linéaire.
CONSERVER CES INSTRUCTIONS
Figure 1
A
B
Minimum
1.5" (3,8 cm)
Minimum
1.5" (3,8 cm)
Minimum
6" (15,3 cm)
Minimum
1.5" (3,8cm)
Minimum
3" (7,6 cm)
C
D
Minimum
3" (7,6 cm)
Minimum
Voir le point 4 et 5
pour la dimension
Minimum
3" (7,6 cm)
www.dimplex.com

Advertisement

loading