Technical specifications
General EWLQ
014
Dimensions HxWxD
(mm)
Machine weight
104
(kg)
Connections
• condenser
discharge
5/8"
connection
(copper)
• condenser liquid
5/8"
connection
(copper)
General EWLQ
Dimensions HxWxD
(mm)
Machine weight
(kg)
Connections
• condenser
discharge
connection
(copper)
• condenser liquid
connection
(copper)
Compressor EWLQ
014
JT140L­P8Y1
Model
Speed
(rpm)
Oil type
Oil charge volume
1,5
(l)
Refrigerant type
Evaporator
Type
62
Min. water volume
(l)
31~75
Water flow range
(l/min)
Condenser
refer to engeneering specifications as published by the supplier of your
remote condenser
Compressor EWLQ
2xJT236DJ­Y1 2xJT315DJ­Y1
Model
Speed
(rpm)
Oil type
2 x 3,0
Oil charge volume
(l)
Refrigerant type
Evaporator
Type
Min. water volume
(l)
101~247
Water flow range
(l/min)
Condenser
refer to engeneering specifications as published by the supplier of your
remote condenser
(1) Refer to the engineering data book for the complete list of specifications.
EWLQ014~064KBW1N
Condenserless water-cooled water chillers
D­EPMHP01108­17EU
025
033
600x600x600
138
149
3/4"
3/4"
5/8"
5/8"
049
064
600x600x1200
252
274
3/4"
3/4"
5/8"
5/8"
033
025
JT236DJ­Y1
JT315DJ­Y1
2900
FVC68D
3,0
3,0
R410A
brased plate heat exchanger
103
155
53~123
76~186
049
064
2900
FVC68D
2 x 3,0
R410A
brased plate heat exchanger
205
311
152~373
(2)
Electrical specifications
Model EWLQ
014
Power supply
• Phase
• Frequency
(Hz)
• Voltage
(V)
• Voltage tolerance
(%)
16gG
• Recommended fuses
(aM)
Compressor
• Phase
• Frequency
(Hz)
• Voltage
(V)
6.5
• Nominal running current (A)
Control
• Phase
• Frequency
(Hz)
• Voltage
(V)
• Recommended fuses
(aM)
049
Model EWLQ
Power supply
• Phase
• Frequency
(Hz)
• Voltage
(V)
• Voltage tolerance
(%)
40gG
• Recommended fuses
(aM)
Compressor
• Phase
• Frequency
(Hz)
• Voltage
(V)
1
• Nominal running current (A)
Control
• Phase
• Frequency
(Hz)
• Voltage
(V)
• Recommended fuses
(aM)
(2) Refer to the engineering data book for the complete list of specifications.
025
033
3N~
50
400
±10
25gG
25gG
3~
50
400
10.5
15.0
1~
50
230
factory installed
064
3N~
50
400
±10
50gG
3~
50
400
0,5
15,0
1~
50
230
factory installed