Torus Power WM 45 BAL Manual

Wm series, engineered to perform & protect like no other, torodial isolation power transformers

Advertisement

Quick Links

WM Series Manual
Warning:
User is responsible for installing this unit in accordance with all
local, provincial/state and federal electrical code requirements.
The installation of this unit requires inspection and approval
by local safety authority. This wall mount unit is not equipped
with a power safety interlock.

Advertisement

Table of Contents
loading

Summary of Contents for Torus Power WM 45 BAL

  • Page 1 WM Series Manual Warning: User is responsible for installing this unit in accordance with all local, provincial/state and federal electrical code requirements. The installation of this unit requires inspection and approval by local safety authority. This wall mount unit is not equipped with a power safety interlock.
  • Page 3: Table Of Contents

    Page 1 Important Safety Instructions..................Page 2 Shipping Carton & Packing Material................Page 2 Page 2 Placement & Ventilation..................... Torus Power WM Series Description................Page 3 Transient Voltage Surge Suppression (TVSS)............... Page 3 Power Sharing Outputs....................Page 3 Circuit Protection......................
  • Page 4: Important Safety Instructions

    15. The power switch should be in the “off” position when devices. connecting or disconnecting equipment from a Torus Power unit. 8. Power Cord Protection—Power cables should be routed so they 16. CAUTION Some units can be very heavy, please use safe are not likely to be stepped on or crushed by items placed on practices when lifting.
  • Page 5: Torus Power Wm Series Description

    Torus Power WM Series Description Torus Power PIUs (Power Isolation Units) combine the best surge suppression with unique toroidal transformer technologies from PLITRON to provide the ultimate performance and protection for sensitive audio and video equipment applications. Balanced input power from two 120V phases provides high input power and noise cancellation.
  • Page 6: Circuit Schematic - North American Wm Model

    Circuit Schematic - North American WM Model (WM 45 BAL TVSS) RETAINER BAND T1,10.2 T1,10.1 T1,3 T1,10 240V 3/L2 4/T2 T1,2 208V T1,10A (J2) TVSS SURGE (J1) T1,9A 1/L1 2/T1 T1,1 T1,9.2 T1,9.1 T1,4 T1,9 T1,5 T1,9B T1,9B.1 DOOR CABINET...
  • Page 7: Layout - North American Wm Model

    INPUT SELECT OUTPUT INPUT 120VAC 240VAC INCOMING GROUND Note: Layout drawing is provided for reference only, Torus Power WM units have no user serviceable parts inside. Please return unit to manufacturer for repair and service when required. www.TorusPower.com Page 5...
  • Page 8: Electrical Specifications - North American Models

    3x20A 120VAC WM 75 BAL 2x40A (Fuses) 5x20A 208VAC, 60HZ WM 100 BAL 2x50A (Fuses) 5x20A 100A WM 45 BAL TVSS 2x25A (Fuses) 3x20A 240VAC, 60Hz WM 60 BAL TVSS 2x30A (Fuses) 3x20A 120VAC WM 75 BAL TVSS 2x40A (Fuses)
  • Page 9: Wall Cabinet External Layout - Wm Series

    Wall Cabinet External Layout - WM AVR Series 14.00" 10.25" 24.37" 25.50" Space around unit as shown above: 'A' = 5.00" 'B' = 6.00" 10.250" Customer electrical connections: Wiring conduit holes should be added as required to this area. www.TorusPower.com Page 7...
  • Page 10: Warranty

    Warranty coverage is not transferrable and original proof of purchase is required for warranty claims. In the event of a warranty claim, Torus Power Inc. will remedy the issue by repair or replacement, as we deem necessary, to restore the product to full performance.