11 Troubleshooting
Fault
Error description
code
119
Fault water pressure
121
Flow temperature 1 (Heating circuit 1) monitoring
122
Flow temperature 2 (Heating circuit 2) monitoring
126
DHW charging monitoring
127
Legionnaire's disease germs temperature not
reached
128
Flame failure during operation
132
Gas pressure Monitor fault
133
No flame during the safety time
146
Configuration fault common message
151
Internal fault
152
Parameterization fault
160
Fan fault
162
Air pressure monitor does not close
171
Alarm contact H1 or H4 activated
172
Alarm contact H2 (EM1, EM2 or EM3) or H5 activated
178
Temperature monitor heating circuit 1
179
Temperature monitor heating circuit 2
183
The device is in parameter setting mode
217
Sensor fault
218
Pressure monitoring
241
Flow sensor solar sensor fault
242
Return sensor solar sensor fault
243
Swimming pool sensor fault
260
Flow temperature 3 sensor fault
270
Monitoring function
317
Mains frequency outside of valid range
320
DHW charging temp sensor fault
322
Water pressure too high
323
Water pressure too low
324
BX same sensors
325
BX / extension module same sensors
326
BX / mixer group same sensors
327
Extension module same function
328
Mixer group same function
329
Extension module / mixer group same function
330
Sensor BX1 no function
331
Sensor BX2 no function
332
Sensor BX3 no function
335
Sensor BX21 no function (EM1, EM2 or EM3)
336
Sensor BX22 no function (EM1, EM2 or EM3)
339
Collector pump Q5 missing
341
Collector sensor B6 missing
342
Solar DHW sensor B31 missing
343
Solar interconnection missing
344
Solar actuator buffer K8 missing
345
Solar actuator swimming pool K18 missing
346
Solid fuel boiler pump Q10 missing
148
Paramount five 30 – 115
Explanations/causes
Check water pressure or fill in water
Lack of gas, contact GW opened, external temperature moni­
tor
Reset, if the fault re-occurs several times contact installer,
lack of gas, polarity of mains connection, safety period, check
ignition electrode and ionization current
Check parameters (see adjustment table installer and/or call-
up values), unlock LMS, replace LMS, installer
Fan possibly defective, speed threshold set wrongly
Check water pressure and drain water if necessary
Check water pressure and top up with water if necessary
1)
1) 3)
1) 3)
3)
1)
1)