Problem
Motor does not run
Suction capacity decreases
Vacuum stops running
Dust comes out while vacuuming
Automatic filter cleaning is not working
Power tool does not turn on
D
WALT Dust Extractor Vacuums (DWV012) are manufactured in compliance with Underwriters Laboratories
e
(UL) 1017 and Canadian Standards Association (CSA) C22.2 No. 243-01 Standards.
These vacuums also meet the requirements of a HEPA vacuum as defined in the United States Environmental
Protection Agency's (EPA) Renovation, Repair and Painting (RRP) Rule (40 CFR Part 745) when used with the
DWV9320 or DWV9330 HEPA filter.
The DWV9320 and DWV9330 HEPA filters have been evaluated per IEST-RP-C001.5,7.2 by an independent third
party to confirm that the filter is capable of capturing particles of 0.3 microns with 99.97% efficiency.
8

TROUBLESHOOTING

Solution
Check power cord, plugs and outlet.
Ensure the on/off /tool control switch is in the ON position ( ).
Remove blockages in the suction nozzle, suction tube, suction hose or filters.
Replace the paper or fleece bag.
Check for proper installation of the filters.
Clean or replace the filters.
Empty canister, refer to Empty Canister under Operation.
Thermal overload has been tripped:
1. Turn the vacuum off and disconnect vacuum cleaner from power source.
2. Empty the canister, if needed.
3. Allow the unit to cool.
4. Plug the power cord into an appropriate outlet and turn on/off/tool
control switch to the ON position ( ) to test. If vacuum will not restart, call
1-800-4-D
WALT (1-800-433-9258).
e
Check for proper installation of the filters.
Ensure filters are not damaged; replace if necessary.
Ensure filter seals are in place and are secure.
Listen for the solenoid clicking to ensure the filter cleaning mechanism
is working.
Ensure the on/off/tool control switch is in the ACTIVATION position

sPECiFiCATiOns

DWV012
Volts
Hertz
Rated Current
Maximum speed current
Minimumm speed current
Capacity
Weight

Compliance Certificate

120 V ~
60
15 A per UL1017
11.6 A
7 A
10 gallon (38 liters)
33.5 lbs (15.1 kg)
.