Perform A Data Dump - Meridian M3902 Description And Installation

M3900 series digital telephones
Hide thumbs Also See for M3902:
Table of Contents

Advertisement

Perform a data dump

M3900 Series Meridian Digital Telephones Description, Installation and Administration
Appendix A: Flash Download procedure
Table 19 summarizes the required steps to perform this procedure.
Table 19
Options 61C,81,81C parallel reload summary
Step
1
2
3
4
5
6
7
8
9
10
11
1
Load the Equipment Data Dump Program (LD 43). At the prompt, enter:
LD 43 to load the program
2
When EDD000 appears on the terminal, enter: EDD to begin the data
dump.
When "DATABASE BACKUP COMPLETE" or "DATADUMP
3
COMPLETE" appears on the terminal, enter: **** to exit the program.
CAUTION
If the data dump is not successful, do not continue;
contact your technical support organization. A data
dump problem must be corrected before proceeding.
Action
Perform a data dump.
STAT the hardware.
Split the Cores.
Install PSDL file on Core/Net 1.
Switch call processing from Core/Net 0 to Core/Net 1.
Test Core/Net 1.
Install software on Core/Net 0.
Exit Split mode.
Test Core/Net 0 and 1.
Synchronize the hard disks.
Perform a data dump.
Page 143 of 174