Jandy Lite2 Installation And Operation Manual page 8

Pool and spa heater
Table of Contents

Advertisement

Page 6
Table 2. Minimum Heater Clearances From Combustible Surfaces
Table 2. Dégagements Minimaux à Assurer Entre les Parois de L'appareil et les Constructions Combustibles
SIDE OF
INDOOR (OUTDOOR SHELTER)
HEATER
INSTALLATION
INCHES
BLANK*
6
REAR
6
PIPING
12
TOP
44
FRONT
ALCOVE**
Avoid placing the heater in locations where it can
cause damage by water or condensate leakage. If this
is not possible, provide a suitable drain pan to catch
and divert any leakage. The pan must not block natural
flow of air around the heater.
All criteria given in the following sections reflect
minimum clearances as stated in the national stan-
dards. However, each installation must also be evalu-
ated taking into account the prevailing local conditions
such as wind speed and direction, proximity and
height of walls that may block ventilation or cause
down drafts, and proximity to public access areas.
2.3.2 Clearances
The heater must be placed to provide clearances
on all sides for maintenance and inspection. There
must also be minimum distances maintained from
combustible surfaces (see Table 2).
At least 20" (500mm) access must be available in
front of the heater for burner removal.
If the heater is to be installed in a garage, or
similar structure, all burners and burner ignition
devices must have a minimum 18" (457mm) clearance
above the floor.
2.3.3 Flooring
The heater shall be installed on a level floor of
noncombustible construction or on fire-resistant slabs
or arches. Noncombustible flooring is defined as
flooring material and surface finish not capable of
being ignited and burning and with no combustible
materials against the underside. Acceptable materials
are those consisting entirely of a combination of steel,
iron, brick, tile, concrete, slate, glass or plaster. Do
not install the heater directly on a combustible wood
or carpet floor without placing a noncombustible
platform between the floor and the heater.
The heater can be installed on a combustible
floor if a noncombustible base assembly, available
from Jandy, is used. See the heater rating plate or the
Parts List (Section 11) of this manual for the appropri-
OUTDOOR INSTALLATION
CENTIMETERS
INCHES
15
6
15
6
30
12
112
OPEN UNROOFED AREA
ALCOVE**
OPEN
Note: Clearances listed in Table 2 are
manufacturer's tested values. These are
given as minimum values. Where local
and national codes apply, and values
CENTIMETERS
are different than those listed in Table
2, use the greater value to ensure safe
15
operation.
15
30
* Refers to side opposite piping
** A closet with no door
(In US-18 in (46 cm) clearance,
OPEN
Notes:
1. Blocks must provide solid base and be braced so they
cannot slip out of place.
2. Air openings in blocks must be arranged to provide
unrestricted opening through entire width or length of
base.
Figure 2. Non-Combustible Platform.
ate base part number. Heaters must never be
installed directly on carpeting.
As an alternative to the Jandy noncombustible
base plate, in the United States, the National Fuel Gas
Code allows a heater to be placed on a combustible
surface when there is a platform under the heater
made of hollow masonry no less than 4 inches (102
millimeters [mm]) thick, covered with sheet metal at
least 24 gauge thick and extending beyond the full
width and depth of the heater by at least 6 inches (152
mm) in all directions. The masonry must be laid with
ends unsealed, and joints matched to provide free
circulation of air from side to side through the masonry
(see Figure 2). If the heater is installed in a carpeted
alcove, the entire floor of the alcove must be covered
by a noncombustible panel.
In Canada-24 in (61 cm) clearance)