4. Drill a 3/16-inch hole in the utility pole at each of the locations marked in step 3.
5. Locate the two 3/8 x 1-1/2-inch lag screws (provided with the enclosure) and place a 3/8-
inch lock washer and 3/8-inch flat washer on each screw.
6. Secure the mounting bracket to the pole using the screws and washers prepared in step 5.
Tighten screws until bracket is securely attached to the plywood.
7. Hang the enclosure from the mounting bracket as shown in
5.3.4
Metal Utility Pole Mounting
Stainless steel strapping is provided for securing the mounting bracket to a cylindrical object
(such as a metal utility pole) that cannot be pierced with a screw or bolt. A special tool (Panduit
BT1HT) is required to properly secure and tension the strapping. Use the following procedure
to install the mounting bracket on a metal utility pole:
1. Insert the two sections of stainless steel metal strapping (provided with the enclosure)
through the slots in the mounting bracket and place in position for mounting as shown in
Figure
8. The end with the V-notch should be at the top.
Note: Two sections of stainless steel metal strapping are provided with the enclosure. If
additional strapping is required, use 5/8-inch wide 304 AISI stainless steel strapping with
a minimum tensile strength of 700 lbs force.
Figure 8. Secure Standard Mounting Bracket To a Metal Pole
MOUNTING
BRACKET
22635-A