SYMPTOM
V. Frequent
pilot
problem.
POSSIBLE CAUSE
C. Defective valve.
D. Plugged burner orifice.
E. Wall switch, or wires defective.
outage
1. Turn valve knob to "ON". Place
1. Check burner orifice for stoppage
1. Follow corrective action in A.1
19
CORRECTIVE ACTION
With the pilot in the ON position,
disconnect the thermopile leads
from the valve. Take a reading
at the thermopile leads. The
reading should be 325 millivolts
minimum. Replace the thermo-
pile if the reading is below the
minimum.
ON/OFF switch to "ON". Check
with millivolt meter at thermopile
terminals. Millivolt meter should
read greater than 100 m.v. If the
reading is okay and the burner
does not come on, replace the
gas valve.
and remove.
above; check switch and wiring.
Replace where defective.