Wiring Diagrams - gledhill Torrent Stainless OV Instruction Manual

Torrent stainless series. open vented stainless steel thermal store providing heating and mains pressure hot water
Table of Contents

Advertisement

INSTALLATION
Overheat
Control
Normally Open
Stat
Stat 2
2 Port Valve
on
on
off
L
N
E
C
1
C
1
2
L
N
E
1
C
1
2
ML
N
PL
SL
E
on
off
Normally Closed
Pipe Thermostat 1
2 Port Valve
Torrent Stainless with 2 pump heating control system and typical solar heating system

WIRING DIAGRAMS

CH & HW Programmer
Room Thermostat
HW
CH
HW
CH
OFF
ON
ON
OFF
N
L
1
2
3
4
E
1
Br
Br
2
3
1
2
3
4
5
6
7
8
9
Local
5
double
A
pole
isolator
L
N
E
SL
L
N
E
boiler
pump
L
N
E
Boiler wiring terminals
Mains supply
230VAC ~ 5 Amp
Page 22
NOTE
Hot Water Programmer and Store Stat
control the boiler in Central Heating mode
Store stat
ON
OFF
ON
OFF
2
3
4
E
C
1
2
Junction
10
11
12
L
N
E
SL
E
C
E
N
L
L
N
E
Boiler hold off pipe thermostat
Type LL641B1012
Temperature range: 50 – 95°C
Typical thermal store
temperature set point 75-77°C,
Boiler pump
Central heating
must be set at a temperature
pump
which prevents the contents
of the thermal store exceeding
100°C. See page 26 for further
guidance. Installer must set the
thermostat correctly during
commissioning.
NOTE
As part of system setup and commissioning, it is important that this boiler hold-off pipe thermostat
be adjusted to find the best setting for each individual installation.
Failure to do so will give under performance of either the boiler or the solar heating system
Solar panels
Solar controller
230Vac
50Hz
Solar
supply
Pump
L N E
L
N E
S2
S1
Boiler hold off pipe thermostat
Type LL641B1012
Temperature range: 50 – 95°C
Typical thermal store
temperature set point 75-77°C,
must be set at a temperature
which prevents the contents
of the thermal store exceeding
1
2
100°C. See page 26 for further
on
off
guidance. Installer must set the
thermostat correctly during
commissioning.
Overheat
NC
E
C
thermostat
(S3)
NOTE
Some solar controllers, the overheat protection is provided by a temperature sensor,S3,
which is wired directly to the solar controller same as sensors S1 and S2
In this case the mechanical overheat thermostat (S3) shown in this diagram is not required and
the solar pump is wired straight to the solar controller.
Page 23
INSTALLATION
PRV
S1
Torrent Stainless SOL
Solar
pumping
station
S3
P1
S2
S1 : Solar flow temperature sensor
S2 : Solar zone store temperature sensor
S3 : Store overheat temperature sensor/Thermostat
WIRING DIAGRAMS