1) Unpack the showcase, and remove the shipping carton, evaporator spacer, tape and
packing material BEFORE operating the unit. Be careful not to damage the exterior
panels when handling the showcase.
2) Position the showcase in a selected site. Clean the interior with soap and water and
rinse thoroughly.
3) Level the showcase in both the left-to-right and the front-to-rear directions.
4) The perimeter where the machine touches the counter should be sealed with silicone.
D. Electrical Connections
* The showcase requires an independent power supply of proper capacity. See the
nameplate for electrical specifi cations. The maximum allowable voltage variation is ±10
percent of the nameplate rating.
* THE SHOWCASE MUST BE GROUNDED. The showcase is equipped with a NEMA
5-15 three-prong grounding plug to reduce the risk of potential shock hazards. It must be
plugged into a properly grounded, independent 3-prong wall outlet.
E. Drain Connections
* The hose may be connected to either right or left joint, whichever is convenient.
* Keep more than 2 vertical inch (5 vertical cm) air gap between the drain pipe end and the
sink.
Joint
Fig. 5
7
Hose
Joint
To fl oor drain or sink