Troubleshooting

Symptom
Water frozen in tank Water frozen in lines or
connections.
Low water flow
Blockage or kinks in valves or
vertical water supply line.
Shut-off valve not set correctly.
Water dripping out of
Seals may need replacing.
valve
Valve does not shut
Worn diaphragm.
off
Drain plugs leak
Worn drain plug or drain plug
screw not tightened.
Possible cause/s
Solution/s to check or action:
Vertical water supply line is properly insulated.
Tank bottom is sealed on concrete.
Livestock are drinking from the WaterPro2, if not, drain and refill
to recycle fresh water.
Vertical water supply line is centered within the thermal earth
tube.
Horizontal water supply line is 1 foot (51 mm) below the frost
line.
Vertical water supply line is free from kinks.
Valve and float assembly has no blockages.
Shut-off valve is set to the open position. See the images of shut-
Using the shut-off valve as a pressure
off valve positions in
reducer
on page 13.
Check water pressure with a pressure gauge.
Check the valve diaphragm and seals.
Check that the valve connections have been tightened.
Valve and float assembly is clear of debris.
The shut-off valve is set to the open position. See the images of
shut-off valve positions in
reducer
on page 13.
Replace valve and float assembly diaphragm.
Check pressure and flow capacity. See
on page 13.
Replace drain plug.
Tighten drain plug.
Using the shut-off valve as a pressure
Pressure and flow capacity
15