Water Quality MultiMeasure Sensor
Included Equipment
Water Quality MultiMeasure Sensor
Stainless Steel Temperature Probe
pH Electrode
Dissolved Oxygen (DO
Conductivity Electrode (10x)
Required Equipment
PASPORT Interface
Optional Equipment
Fast-response Temperature Probe
Skin/surface Temperature Probe
Conductivity Electrode (1x)
Various Ion-selective Electrodes (ISE)
Oxidation Reduction Potential (ORP) Electrode CI-6716
DO
Electrode Maintenance Kit
2
1
The DO
Probe comes with a bottle of filling solution, a syringe, a replacement membrane cartridge
2
and O-ring, and a plunger. See illustration on page 7.
2
PASPORT interfaces include the AirLink (IW-4100 or PS-2005), Xplorer GLX (PS-2002), Xplorer
(PS-2000), PowerLink (PS-2001), and USB Link (PS-2100)
®
PS-2169
1
) Probe
2
2
In s t r u c ti on M an u a l
Part Number
PS-2169
PS-2153
699-195
699-06320
699-06621
See PASCO catalog or
www.pasco.com
PS-2135 (3-pack)
PS-2131
699-06620
See PASCO catalog or
www.pasco.com
CI-6541
0 1 2 - 0 9 3 8 4B

Advertisement

Table of Contents
loading

Summary of Contents for Pasport PS-2169

  • Page 1 Probe comes with a bottle of filling solution, a syringe, a replacement membrane cartridge and O-ring, and a plunger. See illustration on page 7. PASPORT interfaces include the AirLink (IW-4100 or PS-2005), Xplorer GLX (PS-2002), Xplorer (PS-2000), PowerLink (PS-2001), and USB Link (PS-2100)
  • Page 2 DataStudio Setup If you are using a computer, connect the PASPORT interface to the computer and start DataStudio. (Refer to the documentation that came with your PASPORT interface for instructions on connecting it to your computer.) In DataStudio, click the Start button to begin data collection;...
  • Page 3: Measuring Temperature

    M o d e l N o . P S - 2 1 6 9 T e m p e r a t u r e Xplorer GLX Setup If you are using an Xplorer GLX in standalone mode, press to start data collec- tion.
  • Page 4: Conductivity Calibration

    W a te r Q u a lit y M u l ti M e a s u r e S e n s o r p H / IS E/O RP the end of the electrode in the solution to be measured and wait for the reading to sta- Range (mS/cm) 10x probe bilize.
  • Page 5 M o d e l N o . P S - 2 1 6 9 p H / IS E / O R P Measuring pH The pH electrode produces a voltage proportional to the pH of the solution that it is immersed in.
  • Page 6: Dissolved Oxygen

    W a te r Q u a lit y M u l ti M e a s u r e S e n s o r D is s o lv e d O x y g e n Dissolved Oxygen The DO component of the multi-sensor is designed for use in aqueous media at tem- peratures ranging from 0 °C to 50 °C.
  • Page 7 M o d e l N o . P S - 2 1 6 9 D is s o l v e d O x y g e n Calibration Perform a one-point calibration using 100% humidified air as the known standard, which is equivalent to 100% saturated (pure) water.
  • Page 8 W a te r Q u a lit y M u l ti M e a s u r e S e n s o r D is s o lv e d O x y g e n Rinse the electrode with tap water (or deionized water in areas with hard tap water) and rub it with a paper towel to dry it and remove loose silver oxide.
  • Page 9: Specifications

    M o d e l N o . P S - 2 1 6 9 S p e c if i c a t io n s Specifications General Component Sensors Temperature, Conductivity, pH/ISE/ORP probe voltage, Dissolved Oxygen Max. Sampling Rate 20 samples per second (for each component sensor) Default Sampling 2 samples per second...
  • Page 10: Appendix A: Datastudio Calibration

    W a te r Q u a lit y M u l ti M e a s u r e S e n s o r D a t a S t u d io C a l ib r a t io n Appendix A: DataStudio Calibration In DataStudio, click the Setup button to open the Experiment Setup window;...
  • Page 11: One-Point Calibration

    Click to start data collection If you are using the Water Quality MultiMeasure Sensor with a PASPORT interface connected to a computer, you can use EZ-Screen software instead of DataStudio. When the sensor is connected to the computer through the interface (if DataStudio is not running) a window automatically launches giving you the option of launching EZ-Screen.
  • Page 12: Appendix C: Reference Solutions For Conductivity Calibration

    W a te r Q u a lit y M u l ti M e a s u r e S e n s o r R e f e r e n c e S o l u t io n s fo r C o n d u c t iv it y C a l ib r a t io n Appendix C: Reference Solutions for Conductivity Calibration Reference...
  • Page 13 M o d e l N o . P S - 2 1 6 9 C a li b r a ti o n Ta b le s Temp. Atmospheric pressure, in millimeters of mercury and (inches of mercury) °C (31.30) (31.10) (30.91)
  • Page 14 W a te r Q u a lit y M u l ti M e a s u r e S e n s o r C a li b r a t io n Ta b le s Temp. Atmospheric pressure, in millimeters of mercury and (inches of mercury) °C (31.30)
  • Page 15 M o d e l N o . P S - 2 1 6 9 C a li b r a ti o n Ta b le s Temp. Atmospheric pressure, in millimeters of mercury and (inches of mercury) °C (27.36) (27.17) (26.97)
  • Page 16 W a te r Q u a lit y M u l ti M e a s u r e S e n s o r C a li b r a t io n Ta b le s Temp. Atmospheric pressure, in millimeters of mercury and (inches of mercury) °C (27.36)
  • Page 17 M o d e l N o . P S - 2 1 6 9 C a li b r a ti o n Ta b le s Temp. Conductivity, in microsiemens per centimeter at 25 degrees Celsius °C 1000 2000 3000 4000...
  • Page 18 W a te r Q u a lit y M u l ti M e a s u r e S e n s o r C a li b r a t io n Ta b le s Temp. Conductivity, in microsiemens per centimeter at 25 degrees Celsius °C 17000...
  • Page 19 M o d e l N o . P S - 2 1 6 9 C a li b r a ti o n Ta b le s Temp. Conductivity, in microsiemens per centimeter at 25 degrees Celsius °C 34000 35000 36000 37000...
  • Page 20 W a te r Q u a lit y M u l ti M e a s u r e S e n s o r C a li b r a t io n Ta b le s Temp. Conductivity, in microsiemens per centimeter at 25 degrees Celsius °C 51000...
  • Page 21: Technical Support

    PASCO scientific, is prohibited. Trademarks PASCO, PASCO scientific, DataStudio, MultiMeasure Sensors, PASPORT, and ScienceWorkshop are trademarks or registered trademarks of PASCO scientific, in the United States and/or in other countries. All other brands, products, or service names are or may be trademarks or service marks of, and are used to identify, products or services of, their respective owners.