Whirlpool Cabrio Service Manual page 10

Maytag, kenmore 900 series
Hide thumbs Also See for Cabrio:
Table of Contents

Advertisement

Available languages

Available languages

FOR SERVICE TECHNICIAN'S USE ONLY
SERVICE FAULT/ERROR CODES
CODE
DESCRIPTION
F1E1
Motor Relay
Stuck On
F1E3
Incorrect Controller
Installed (on electric
models only)
F1E5
Parameter Memory
Invalid
F2E1
User Interface (UI)
Stuck Button
F2E4
UI Software Error:
Incompatible
Parameter File
F2E5
UI Software Error:
Parameter Memory
Invalid
F3E1
Exhaust Thermistor
Open/Shorted
F3E2
Moisture Sensor
Open/Shorted
F3E3
Inlet Thermistor
Open/Shorted
F4E1
Heater 1 Failure or
Connector Problem
F4E2
Heater 2 Failure or
Connector Problem
(on electric
models only)
F4E3
Restricted Airflow
F4E4
L2 Line Voltage
Error
(on electric
models only)
F6E2
Communication Error: Communication between the ACU and UI has not been detected.
UI Cannot Hear ACU
F6E3
Communication Error: • Check the harness continuity and connections between the ACU
ACU Cannot Hear UI
PAGE 10
EXPLANATION AND RECOMMENDED PROCEDURE
Indicates an ACU problem.
• Replace the ACU.
Verify that the part numbers of the ACU and the User Interface are
correct for the dryer model displaying the fault/error code. Replace
the ACU and/or UI that does not match.
ACU parameter file missing; replace the ACU.
Indicates a stuck button (depressed for over 20 seconds).
This fault code will ONLY appear when in the service diagnostic
mode. See TEST #6: Buttons and Indicators, page 22.
Replace the User Interface.
Replace the User Interface.
Indicates that the exhaust thermistor is open or shorted. If the
temperature drops below 18° F (> 50k ohms), the exhaust
thermistor is open. If the temperature is above 250° F (< 500
ohms), the exhaust thermistor has shorted. May occur if the
P14 connector is not plugged into the ACU. See TEST #4a:
Thermistors, page 18.
Indicates the moisture sensor strip is open or shorted.
This fault code will only appear when in the service diagnostic
mode. See TEST #5: Moisture Sensor, page 21.
Indicates that the inlet thermistor is open or shorted. If the
temperature drops below 18° F (> 245k ohms), the inlet
thermistor is open. If the temperature is above 391° F (< 328
ohms), the inlet thermistor has shorted. See TEST #4a:
Thermistors, page 18.
Indicates no voltage detected at the heater relay.
• Unplug dryer or disconnect power and check that the wires
are plugged into the heater element(s) and the relay(s) on
the ACU.
Indicates no voltage detected at the heater relay.
• Unplug dryer or disconnect power and check that the wires
are plugged into the heater element(s) and the relay(s) on
the ACU.
Indicates low airflow that may affect dryer performance.
• Confirm that airflow system is not blocked; check lint screen,
exhaust duct, exhaust fan.
Indicates low L2 voltage (less than 50 V) is detected at the ACU.
• Check to see if a household fuse has blown or a circuit breaker
has tripped.
• Confirm the power cord is properly installed and plugged
into the power outlet.
• Unplug dryer or disconnect power and check the relay
connections on the ACU.
• Gas Models Only: Unplug dryer or disconnect power and check
the P14 connection on the ACU (harness loopback on pins 4 & 5).
• Unplug dryer or disconnect power.
and UI.
• Check AC and DC supplies. See TEST #1: ACU Power Check,
page 12.
• Replace the User Interface.
• Replace the ACU.