Communicator Tests; Flag A' Options - ADE Accenta G3 Engineering Information

Intruder alarm system
Hide thumbs Also See for Accenta G3:
Table of Contents

Advertisement

Accenta/Optima G3 intruder system

Communicator tests

Note: These tests are not applicable to
Optima compact G3 panel.
Example: To test intruder output
and thereafter stop the test.
Prog
9
9
9
0
Reset
Reset
Enter Engineer program mode
Communicator
2
Tests
Attack
Factory defaults
Fire Output
1
2
PA Output
Intruder
3
Output
Open /Close
4
Output
5
Abort Output
Confirmed
6
Output
Communicator fault
0 Stop the tests
Exit current level
Reset
Reset
Leave engineer mode
Day
Acknowledge
The Zone 8 LED is lit to show there is a
communicator line fault.
Flag A descriptions:
Silent PA : When this flag is set and on
operating PA will cause a Silent PA alarm.
RKP PA Enable: When this flag is set the
keypad PA buttons are enabled.
Engineer Reset: When this flag is set an
Engineer code must be entered to reset the
system after a full alarm. When the flag is clear
the system can be reset by the user.
Anti-code Reset: When this flag is set it enables
the anti code reset function.
4PI175 issue 1_6/01

'Flag A' Options

9
2
3
Appropriate
Zone indicator
is lit to show a
selected output
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 8
Attack
Tamper
Enable Door bell on PTS: When this flag is set
it allows a zone circuit programmed as PTS to
operate as a door bell.
Enable single key setting:When this flag is set
it allows the panel to be set by pressing the SET
button (ie code entry is not needed), however a 4
digit code is needed to Unset the panel.
Enable strobe on setting: When this flag is set
the external strobe will flash for 3 seconds once
the panel has successfully set.
Enable external Fire bell: When this flag is set
the system bell will sound 3 seconds On / 3
seconds Off during a fire alarm.
Engineering information
Example: To set the panel for
engineer reset, Press:
Prog
9
9
9
9
Reset
Reset
Enter Engineer program mode
Appropriate
3
Flags A
Zone indicator
is lit to show
Attack
flag setting
Zones 1-8
Momentarily On
Silent PA
1
RKP PA enable
2
3
Engineer reset
Anti-code reset
4
Enable Door bell
5
on PTS
Enable single
6
key setting
Enable strobe
7
on setting
Enable Bell
8
in Fire
Exit current level
Reset
Reset
Leave engineer mode
Day
Acknowledge
3
3
Factory defaults
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Attack
Tamper
17