ADE Accenta G3 Operating Instructions Manual

ADE Accenta G3 Operating Instructions Manual

Intruder alarm system
Hide thumbs Also See for Accenta G3:

Advertisement

ZONE
1
2
3
4
5
6
7
8
0
1
2
3
5
6
7
8
CHIME
OMIT
RESET
PROG
SET
TA
Servicing organisation details
Servicing organisation (Installer) name: ____________________________________
Telephone number: _____________________________________________________
Date of installation: _____________________________________________________
Account number: _______________________________________________________
Intruder alarm system

Operating Instructions

4
PA
9
PA
Day
Power
1 2 3 4 5 6 7 8
ZONES
G3
mini
A
ccenta
0
1
2
Power
Attack
5
6
7
Tamper
Chime
Omit
Reset
Day
3
4
PA
8
9
Prog
Set
1

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Accenta G3 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for ADE Accenta G3

  • Page 1: Operating Instructions

    Intruder alarm system Operating Instructions ZONE 1 2 3 4 5 6 7 8 Power ZONES Attack Tamper CHIME OMIT RESET PROG Prog Chime Omit Reset Power mini ccenta Servicing organisation details Servicing organisation (Installer) name: ____________________________________ Telephone number: _____________________________________________________ Date of installation: _____________________________________________________ Account number: _______________________________________________________...
  • Page 2 Operating instructions System installation Fire Zones This booklet tells you how to operate your One or more Zones on your alarm system may intruder alarm system. To simplify this booklet have a Fire or Smoke detector connected to it. In we have assumed that the alarm system has been the event of a fire the alarm system will produce installed by a professional intruder alarm system...
  • Page 3: How To Set System

    Accenta/Optima G3 intruder system How to set the system When you leave your premises you will need to set (or turn on) the intruder alarm system. Before setting the system you should ensure that 1 2 3 4 5 6 7 8 Power the premises have been completely vacated and ZONES...
  • Page 4: How To Unset System

    Operating instructions How to Unset the system When you enter your premises you will need to unset (or turn off) the system. Enter your premises by the route recommended Entry beeps by your installer. The system will produce an 1 2 3 4 5 6 7 8 Power entry beep tone.
  • Page 5: How To Part Set System

    Accenta/Optima G3 intruder system How to part set the system If your installer has programmed your system for part set operation you will be able to set some zones of the system while others remain unset. Part set operation is often used at night time, and it will permit you to freely walk around the bedrooms while the living area and outside doors are protected.
  • Page 6: How To Silence An Alarm

    Operating instructions How to silence an alarm If your system goes into alarm then be aware that intruders may be in the premises. Seek assistance before investigating the cause of the alarm. External siren Enter your code 1 2 3 4 5 6 7 8 Power The alarm will stop, and the Zone, TA (Tamper) ZONES...
  • Page 7: How To Reset After An Alarm

    Accenta/Optima G3 intruder system How To Reset After An Alarm After any alarm you will need to reset your system so that it can be used normally. Your installer may have programmed the system to be reset by you, the installer, or by Anti-code. Strobe Off Reset Press the...
  • Page 8: How To Omit Zones

    Operating instructions How to Omit zones If you cannot set the alarm system because a detector is faulty and in constant alarm you may need to omit its zone from the alarm system. A zone which has been omitted cannot cause an alarm. Key in your code to start the exit procedure.
  • Page 9: How To Set Up Chime Zone

    Accenta/Optima G3 intruder system How to set up Chime Zone Chime is a low security facility for use when the system is unset. It is particularly useful in a shop to warn of customers presence, or in a house to warn when a back door has been opened. When a Chime zone detects movement the system will produce a brief two–tone sound, and the Zone indicator will light.
  • Page 10: How To Change User Code

    Operating instructions How to change your User code You should change your main code regularly to prevent potential intruders from knowing your code. All codes are 4 digits long. The factory set main code is but this may have been changed. 1 2 3 4 5 6 7 8 Power Prog...
  • Page 11: How To Change Your Second Code

    Accenta/Optima G3 intruder system How to change your second code Your alarm system can have a second user code. You may find it useful to set-up this second code for use by a neighbour for use when you are on holiday. The second user code operates like your user code, but it cannot be used to change or delete your code.
  • Page 12: How To Change The Duress Code

    Operating instructions How to change the Duress code Your alarm system can have a duress code. The Duress code is used in a hold-up situation where there is pressure to set or unset the system. The Duress code operates like your normal code but in addition it will silently send a signal to the Alarm Receiving Centre who will inform the Police.
  • Page 13: How To View The Event Log

    Accenta/Optima G3 intruder system How to view the event log The event log keeps a memory of the last 8 alarm events. 1 2 3 4 5 6 7 8 Power Prog Press and enter your code ZONES Attack The TA (Tamper) indicator will light and the Day Tamper Panel indicator will go out to indicate that you are in...
  • Page 14: How To Test Alarm System

    Operating instructions How to test your alarm system You should check that your alarm system still works correctly by periodically carrying out the alarm system tests described here. How to test the Strobe, External Siren and Internal Sounders 1 2 3 4 5 6 7 8 Power Prog Press...
  • Page 15: Walktest

    Accenta/Optima G3 intruder system Walktest Press to carry out a walktest. Walk around your property, and in turn cause each of the detectors to go into alarm. Also, open and close all door and windows that are protected by the system. For each detector (including door or window sensor) that is activated the system will produce a series of beeps, and the associated zone indicator will light.
  • Page 16: For Technical Support

    Operating instructions External siren Time:_____________________________ Siren delay______________________________ Area Zone name Program Program Program protected Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Zone 7 Zone 8 T = Timed (Entry/Exit - Zone) TI = Time Inhibited (Access zone to keypad) I = Immediate (All zones armed to give full alarm) For Technical Support : 0906 302 0999...

This manual is also suitable for:

Optima g3

Table of Contents

Save PDF