First Power Up; Mains Connection - ADE Accenta G3 Engineering Information

Intruder alarm system
Hide thumbs Also See for Accenta G3:
Table of Contents

Advertisement

Accenta/Optima G3 intruder system

First Power up

Before power up for Optima compact only - fit
the top cover on to the base and connect the
speaker wires. Leave the cover in position
throughout the reset of the installation.
a.
Check that the factory fitted links are
connected to terminals PA, TAMP and
T-A.
b.
Fit the battery wires to the BATT
terminals on the PCB, Red to + and
Black to -.
F1
Panel
1.6A
+
-
BATT
(red)
+
-
Black
12V battery
c.
On connecting the battery the system
will now go into alarm condition and
Tamper is indicated
Tamper
and there is an audible
Alarm
indication.
d.
Fit the cover to hold down the tamper
spring at the bottom centre of the PCB.
e.
Enter the user code:
0
1
2
3
0123). The alarm condition will cease
and the system will go to Day mode
Day
.
f.
Immediately enter the engineer code
Prog
9
9
9
The system is now in Engineer
program mode and can be
programmed. Note the
Tamper
Tamper indicator is lit.
4PI175 issue 1_6/01

Mains Connection

The mains power should be connected using a
3 core cable of not less than 0.75mm sq. from a
fused spur to the mains connector inside the
control panel. The 2 Amp fused spur must be
Board
located close to the control panel.
J4
AC
N
E
L
125mA Fuse
Transformer
.
(factory set at
ÿ
9
.
On connecting the mains supply to the panel the
power indicator is lit.
Engineering information
Note: The G3 range of panels are not
supplied with wire links for unused
zones. All unused zones must be
programmed out by setting them to
disabled using the Zone Type function
see page 19.
Dedicated mains supply
from consumer unit.
2A Fused Spur unit
Panel
F1
Board
1.6A
+
-
BATT
(red)
+
-
Black
Transformer
12V battery
Note: The mains supply must be
connected by a technically competent
person and according to current IEE
regulations.
CAUTION: To avoid the risk of
electrical shock you must always totally
isolate the mains supply before opening
the control panel cover(s).
Mains Input Fuse rating: 125mA, 250V type
T (anti surge) and of a type approved to IEC
127 part 2 sheet III.
Power
J4
AC
N
E
L
125mA Fuse
11