Gilson SS-12R Operating Manual

Sieve shaker
Hide thumbs Also See for SS-12R:

Advertisement

OPERATING MANUAL
Gilson Sieve Shaker
SS-8R & SS-12R
Rev: 08/25/2016
PHONE: 800-444-1508
FAX:
P.O. Box 200, Lewis Center, Ohio 43035-0200
800-255-5314
740-548-7298
E-mail: customerservice@gilsonco.com
Website: www.globalgilson.com
740-548-5314

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SS-12R and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gilson SS-12R

  • Page 1 OPERATING MANUAL Gilson Sieve Shaker SS-8R & SS-12R Rev: 08/25/2016 PHONE: 800-444-1508 FAX: P.O. Box 200, Lewis Center, Ohio 43035-0200 800-255-5314 740-548-7298 E-mail: customerservice@gilsonco.com Website: www.globalgilson.com 740-548-5314...
  • Page 2: Safety Instructions

    ALWAYS make sure the motor and other electrical components are appropriate and properly configured for your intended use and available power source. The standard Gilson Sieve Shaker comes with a 1/3hp motor wired for 115V/60Hz. Sieve shakers can also be ordered with special wirings: 230/60, 110/50, and 220/50.
  • Page 3: Table Of Contents

    Gilson Company, Inc. Gilson Sieve Shaker: SS-8R & SS-12R Table of Contents Page Safety Instructions Table of Contents Introduction Unpacking & Set-Up Operating Instructions Sieve Stack & EZ-Clamp Assembly Timer Set-Up & Operation Maintenance Routine Annual Maintenance Disassembly Troubleshooting Parts Diagram SS-8R &...
  • Page 4: Introduction

    1. The SS-8R and SS-12R weigh approximately 135lb Please read understand all safety and operating instruc- and 162lb, respectively. Use appropriate equipment tions for the Gilson Sieve Shaker before putting it into service. and manpower to uncrate the sieve shaker. Wear safety glasses and work gloves.
  • Page 5: Timer Set-Up & Operation

    (9999sec x 1 second) • D = MMMM (9999min x 1 minute) When using 8in sieves on the Model SS-12R, always use (H is for hours, M for minutes, and S for seconds.) To the platform adapter to compensate for the difference adjust the timer mode, press and hold both <UP>...
  • Page 6: Disassembly

    Readjust level via leveling legs, and lock with lock nuts. 1. Disconnect and lock out the power supply. b. For Model SS-12R, be sure that weighted platform 2. Locate the four cover-mounting screws, and remove adapter is used when using 8in diameter sieves.
  • Page 7: Parts Diagram

    Gilson Company, Inc. Gilson Sieve Shaker: SS-8R & SS-12R 6.0 PARTS DIAGRAM: 6.1 SS-8R & SS-12R SS-8R & SS-12R Parts Diagram Page 7...
  • Page 8: Parts List

    Push Button & Spring Roller Clutch Block Cam Shaft Spacer ¹ Serial No. 5499 and lower use old-style clamping system. Contact Gilson for repair Cam Shaft Nylon Washers parts or order Conversion Kit to EZ-Clamp System. ² Serial No. SS-1529 and lower have 23-1/4in long Clamp Rods.
  • Page 9: Additional Information

    Common coarse sizes are also listed. Normally, every second or fourth size is used, Gilson stocks the widest range and largest quantity of although precision testing may require consecutive sizes. sieves of any major supplier. Immediate shipment is Additional sieves are often inserted into the sequence to available for all popular sizes.
  • Page 10: Test Sieve & Screen Tray Verification & Services

    There have been extensive revisions to the newest version of ASTM standard E 11, Specification for Wire • Covers are not necessary with most Gilson sieve shakers, Cloth and Sieves for Testing Purposes. Gilson is leading but may be needed if using a different shaker or shaking the way in educating our customers about the new by hand.
  • Page 11 Master-Matched Sieves are ASTM 8in diameter stainless woven-wire sieves from No.8 (2.36mm) to No.325 (45µm) that have been measured and shown to closely match a set of master sieves maintained by Gilson in a reference laboratory. Master-Matched Sieves from Gilson are always Certificate of E 11...
  • Page 12: 8In Diameter Astm Test Sieves

    Gilson Company, Inc. Gilson Sieve Shaker: SS-8R & SS-12R 8in Diameter ASTM Test Sieves 8IN DIAMETER ASTM TEST SIEVES Brass Cloth Stainless Cloth Stainless Cloth ASTM Brass Frame Brass Frame Stainless Frame Full Ht. Half Ht. Full Ht. Half Ht.
  • Page 13: 12In Diameter Astm Test Sieves

    Gilson Company, Inc. Gilson Sieve Shaker: SS-8R & SS-12R 12in Diameter ASTM Test Sieves 12IN DIAMETER ASTM TEST SIEVES Brass Cloth Stainless Cloth Stainless Cloth ASTM Brass Frame Brass Frame Stainless Frame Full Ht. Inter. Ht. Half Ht. Full Ht.
  • Page 14: Iso 200/300Mm Test Sieves

    Gilson Company, Inc. Gilson Sieve Shaker: SS-8R & SS-12R 8.5 ISO 200/300mm Test Sieves ISO 200/300MM TEST SIEVES 200mm 300mm Stainless Cloth Stainless Cloth Stainless Cloth ISO 565, Brass Frame Stainless Frame Stainless Frame 3310-1 Full Ht. Half Ht. Full Ht.
  • Page 15: Accessories

    Tapping Sieve Shakers. Each adapter is designed to compensate for weight differences as well as frame diameter. SSA-810 and SSA-811 fit either sieve shaker, and must be used in conjunction with the included adapter when using with the SS-12R. The SSA-812 for 10in (254mm) sieves is for use with the SS-12R only.