Lincoln Electric POWER WAVE R350 Operator's Manual page 29

Hide thumbs Also See for POWER WAVE R350:
Table of Contents

Advertisement

E-3
The following is a partial list of possible error codes for the POWER WAVE
the Service Manual for this machine.
MAIN CONTROL BOARD ( "STATUS" LIGHT)
Error Code #
36
Thermal error
54 Secondary (Output) over current error
56 Chopper communication error
58 Primary Fault error
Other
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your
Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.
TROUBLESHOOTING
Observe all Safety Guidelines detailed throughout this manual
ERROR CODES FOR THE POWER WAVE
Indication
Indicates over temperature. Usually accompanied by Thermal LED.
Check fan operation. Be sure process does not exceed duty cycle
limit of the machine
The long term average secondary (weld) current limit has been
exceeded. NOTE: The long term average secondary current limit is
325 amps.
Indicates communication link between main control board and chop-
per has errors. If cycling the input power on the machine does not
clear the error, contact the Service Department.
Review error code from input board status light or status beeper.
Most likely caused by an over power condition which caused an
under voltage on the primary bus. If cycling the input power on the
machine does not clear the error, contact the Service Department.
Error codes that contain three or four digits are defined as fatal
errors. These codes generally indicate internal errors on the Power
Source Control Board. If cycling the input power on the machine
does not clear the error, contact the Service Department.
POWER WAVE
®
CAUTION
R350
®
R350
®
R350. For a complete listing consult
E-3