Advanced Setup
2� Highlight a relay mode, then press ENTEO�
3� Press BACKSPACE to return to the Relay Output menu�
4� Highlight OELAY 1 SETTINGS or OELAY 2 SETTINGS, then press ENTEO� The
settings vary, depending on the mode selected� The settings are:
Option
OUTPUT SOURCE
SCALING FACTOR
UNITS
MIN-ON-TIME
LATCHING
SET HIGH
SET LOW
SET DELAY
RELEASE DELAY
OVERRIDE
5� Highlight OUTPUT SOUOCE, then press ENTEO�
6� Choose the parameter to be transmitted from the relay, then press ENTEO.
7� Press BACKSPACE to return to the settings menu�
8� To edit the remaining settings:
a� Highlight the applicable setting, then press ENTEO�
b� Use the soft keys and numeric keypad to enter a value, then press ENTEO to
save the value�
9� On the confirmation screen, press ENTEO to confirm any change�
Page 36
Description
Parameter assignment (such as flow or total)
Pulse(s) transmitted per unit of measure
Converts output unit of measure
Time, in milliseconds, that the relay will remain in active state
Leaves relay in triggered state until it is manually cleared
Sets the high value for the relay trigger
Sets the low value for the relay trigger
Time in milliseconds (ms) that will elapse before the relay triggers, if
trigger condition is met
Time, in milliseconds (ms) that the relay will remain triggered after
trigger condition is remedied
ONLY ACTIVE IN MANUAL MODE: Bypasses any programmed triggers
to trigger relay� Will remain triggered until deactivated
Table 26: Relay settings