Important Considerations
Electrical Service
110V, 60Hz, 15Amp GFCI protected grounded circuit MUST be used to supply power each individual pedicure spa.
And the main circuit breaker MUST be at 25Amp. For maximum of two units per each electrical outlet.
Water Supply
All plumbing connections must conform to local codes.
Water supply to the spa should be provided with adequate water pressure and water temperature.
Water pressure
To fill the basin correctly up to level, Normal water pressure of 30 to 80 P.S.I is required.
Water temperature
The hot water supply temperature must not exceed 140 . Adjust your hot water accordingly. For hot and cold water supply
fittings and drain fittings location, see below diagram .Carefully connect the water supply line to the appropriate fittings
located on the rear of the pedicure spa.
Pressure / Temperature
Maximum Pressure: 150 psi (10 bars)
Minimum Pressure: 10 psi (69kPa)
Working Temperature: 33F to 140F constant; intermittent to 180f
Maximum Recommended Flow: 15gpm (571pm)
Backflow Preventive Device (Dual Check Valve)
All J&A pedicure spas are equipped with Back flow Preventive Device Dual Check Valve as standard.

Specification

Tested and certified to meet ANSI/ASSE standard 1024. CSA certified to standard No.B64.6
ANSI - American National Institute, ASME - American Society of Mechanical Engineers, CSA - Canadian Standard
Association IAPMO - International Association of Plumbing and Mechanical Officials, UL - Underwriters Laboratory
** Vaccum Breaker
Due to Town and / or State requirement/s are varies in building code, if the Town and / or State requires
Vaccum Breaker, As the Plumber MUST provide Vaccum Breaker according to building code
requirement.
Drain Facilities
The pedicure spa Drain must meet local plumbing codes. Check valve for Drain (not Provided) Must be installed by a licensed
plumber. Also Pedicure spa must be securely fasten to the floor.

Installation Summary

The installation must comply with local, state, and federal building, plumbing and electrical codes, where applicable. A
licensed plumber should complete the plumbing of the pedicure spa.
Note: Failure to comply with federal, state, or local codes and ordinances will result in warranty being nullified and
void.
(0.6C to 60C sustained; intermittent to 82.2C)