BIOS Error POST (Beep) Codes
During the POST (Power-On Self-Test) routines, which are performed each time the system is
powered on, errors may occur.
Non-fatal errors are those which, in most cases, allow the system to continue the boot-up
process. The error messages normally appear on the screen.
Fatal errors are those which will not allow the system to continue the boot-up procedure. If a
fatal error occurs, you should consult with your system manufacturer for possible repairs.
These fatal errors are usually communicated through a series of audible beeps. The table
shown below lists some common errors and their corresponding beep codes encountered by
users.
Beep Code
Error Message
1 beep
Refresh
5 short, 1 long
Memory error
5 long, 2 short
Display memory read/write error
1 long continuous
System OH
Appendix A
BIOS Codes
BIOS Beep (POST) Codes
Description
Circuits have been reset (Ready to power up)
No memory detected in system
Video adapter missing or with faulty memory
System overheat condition