Samsung SCX-RD100 User Manual page 8

Coaxial remote controller
Table of Contents

Advertisement

Introduction
RS-485 TERMINATION & PROTOCOL Setting Switch
- You can select to set the RS-485 termination.
- Turn this switch ON, if RS-485 termination is required.
ON
ON
ON
1
2
1
1
TERMINATION
- For multi-protocol settings, you can set the protocol and baud rate, and
selection of COAXIAL/RS-485 or RS-232.
ON
ON
ON
1
1
2
2
TERMINATION
TERMINATION
- Use pin 1,2,3,4 of the Protocol setting switch to select a protocol.
- Use pin 5,6 of the Protocol setting switch to select a baud rate.
- Use pin 7 of the Protocol setting switch to select COAXIAL/RS-485 output.
- Use pin 8 of the Protocol setting switch to select RS-232 input.
Address Switch
- For RS-232 / RS-485 communications, you can use this switch to set the address.
ADDRESS
(X)100
- Set the address by using three switches shown above.
- From the left, the number is hundreds, tens and ones place, respectively.
The effective range of valid address is between 0 and 255 (1~255 for multi-
protocol).
If you specify the address as other than between 0 and 255, it will be set to 0.
NOTE
Menu Navigation Key
Use this to navigate through the menus.
8 – COAXIAL REMOTE CONTROLLER