Use. This option is useful for the motored flights, when the sound of the engine muffles the
beeper of the variometer. It is also useful for saving energy (in case of a small energy reserve,
the beeper should be turned off, leaving only a light indication).
MENU 5
MENU 6
briefly pressing "Button 3". The initial value after switching on the device is -3.0 m/s.
This option will help to detect the falling in a timely manner and warn the pilot about it.
If the flight altitude is more than 100 meters, the following warning will be displayed on
the screen: "ALARM! FALLING! "(The first line), as well as the relative height above the start
level
at the moment (second line). In addition, a two-tone audio signal will be output, and
simultaneously the red and green vario indicator lights will turn on and off.
If the height is less than 100 meters, the recommendation on the top line will be to open
the rescue parachute "DEPLOY PARACHUTE", on the second line, the remaining height will still
be displayed. The alarm will switch to more high-tonal, and the light indicators will flash
alternately rapidly.
When the vertical speed is normalized, the alarm will be turned off, the screen will return
to the previous state.
WARNING! This function operates based on the relative altitude above the start level data
It is necessary to zero the relative altitude before the flight!
Turn the variometer LED indication ON/OFF to duplicate
or replace the beeper. The ON/OFF value is selected by
briefly pressing the "Button 3".
Turn ON/OFF the sound confirmation of pressing the
buttons. The ON/OFF value is selected by briefly
pressing the "Button 3".
Setting the threshold value for the activation of sound
and light alarms in the event of a falling. The value is
selected from the list {OFF, -2.5, -3.0, -4.0, -5.0} by
9
!