C. Mount and Position the Camera
1. Install the camera at the site. Be sure to have the required accessories and tools available.
2. Verify that the camera is mounted at a minimum height of 4 meters (13 feet).
3. Select the Live screen.
4. Adjust the zoom so that it includes the required Field of View.
5. Adjust the focus. Use the Push button to automatically focus the lens.
6. Refer to the User and Installation Guide as necessary.
D. Auto-Calibrate the Camera
From the navigation bar, select the Settings > Analytics > Depth tab. The web interface
opens on the Depth > AUTO screen. Verify that the camera is installed at a height of at
least four meters (13 feet) and that the horizon is less than 30% of the Field of View.
1. From the Units drop-down list, select Feet or Meter.
2. Select Set camera height and enter the estimated camera height.
3. Click START. The camera automatically calibrates the depth. Be sure that a person is
walking along the Y (Vertical) axis of the FoV while Auto Calibration is in process.
4. Verify that the horizon, camera height, and human marker settings are correct.
5. Click MANUAL and finish configuring depth settings.
· While Auto Calibration is in progress, you can proceed to steps E (Select rule) and
F (Detect).
· The Auto Calibration finishes when the progress bar reaches 100%. If you stop the
procedure before it finishes, the analytic process will reset.
· If you change from Auto to Manual mode, you must wait until the analytic process resets in
order to use Manual mode.
E. Select Rule
From the navigation bar, select Analytic > Rules. A rule for detecting humans or vehicles
entering the scene (blue masked area) is defined by default. You can activate rules, modify
settings, delete, or add a new rule. To create a new rule:
1. Click NEW.
2. Select the rule type by clicking the link.
3. Draw on the video scene where you want the detection to take place.
4. Define the attributes for detection from the Basic and Advanced tabs.
5. When finished, click APPLY to save the settings.
F. Detect
1. Select the Live tab.
2. Click ARM. The camera is ready for use.
3. Click the red recording icon to start recording.
G. Attach to Latitude
1. In Latitude, click Physical View on the sidebar.
2. On the Navigation Tree, click the system name.
3. From the Discovery tab, do the following:
4. In the Discovery table, right-click the camera.
5. Click Attach.
6. Click the Archiver name to attach.
7. Click Save.
FLIR Systems, Inc.
CB-5222_QIG_3May17_v1
Tel: +1 888.388-3577
Analytic performance is optimized only after the auto depth calibration process is completed.
a. Under Cameras and Encoders, select IOimage (Latitude 7) or FLIR (Latitude 8).
b. Click Start. The camera details are displayed in the Discovery table.
c. If the camera was not discovered, click Discover Unit Manually.
d. Enter the camera's IP address and select ioimage (Latitude 7) or FLIR and Auto Detect
(Latitude 8).
e. Click OK.