OSO HOTWATER Delta Geocoil - DGC 300 Installation Manual

OSO HOTWATER Delta Geocoil - DGC 300 Installation Manual

200-300 l
Hide thumbs Also See for Delta Geocoil - DGC 300:
Table of Contents

Advertisement

Available languages

Available languages

SIKKERHETSINFORMASJON
FDV INFORMASJON
MONTASJEANVISNING
TDS - TECHNICAL DATA SHEET
SAFETY INFORMATION
O&M INFORMATION
INSTALLATION MANUAL
TDS - TECHNICAL DATA SHEET
Manufactured by OSO Hotwater AS
Industriveien 1 - 3300 Hokksund - Norway
Tel: +47 32 25 00 00 / Fax: +47 32 25 00 90
E-mail: oso@oso.no / www.osohotwater.com
146050-00 - 02-2018
Delta Geocoil - DGC
200-300 l.
NO-EN

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Delta Geocoil - DGC 300 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for OSO HOTWATER Delta Geocoil - DGC 300

  • Page 1 SAFETY INFORMATION O&M INFORMATION INSTALLATION MANUAL TDS - TECHNICAL DATA SHEET Manufactured by OSO Hotwater AS Industriveien 1 - 3300 Hokksund - Norway Tel: +47 32 25 00 00 / Fax: +47 32 25 00 90 E-mail: oso@oso.no / www.osohotwater.com...
  • Page 2: Table Of Contents

    INNHOLDSFORTEGNELSE 1. Sikkerhetsinstruks ..........3 Generell informasjon ........3 1.2 Sikkerhetsinstruks for brukeren ..... 4 1.3 Sikkerhetsinstruks for installatøren ..4 2. Produktbeskrivelse ..........5 2.1. Produktidentifikasjon ........5 2.2. Bruksområde ........... 5 2.3 CE merking ............5 2.4 Tekniske data ........... 5 2.5.
  • Page 3: Sikkerhetsinstruks

    1. SIKKERHETSINSTRUKS 1.1 Generell informasjon • Les følgende sikkerhetsinstruks grundig før installering, vedlikehold eller justering av varmtvannsberederen. 60 70 • Personskade eller materiell skade kan °C oppstå hvis produktet ikke monteres eller brukes på tiltenkt måte. • Oppbevar denne manualen og andre rele- vante dokumenter slik at de er tilgjengelige for fremtidig referanse.
  • Page 4: Sikkerhetsinstruks For Brukeren

    1.2 Sikkerhetsinstruks for brukeren ADVARSEL Sikkerhetsventilers overløp skal IKKE tettes eller plugges (sikkerhetsventil medfølger ikke). Produktet skal IKKE tildekkes foran el. lokk i front. Produktet skal IKKE modifiseres eller endres fra sin originale tilstand. Barn skal IKKE leke med produktet, og ikke oppholde seg ved produktet uten tilsyn. Produktet skal være fylt med vann før strøm tilkobles.
  • Page 5: Produktbeskrivelse

    EN 60335-2-21 Produktet er i samsvar med direktiver for: • Sveisestandard EN ISO 3834-2 • Lavspenning LVD 2014/35/EU • Elektromagnetisk kompatibilitet EMC 2014/30/EU OSO Hotwater AS er sertifisert iht. • Trykkutstyr PED 2014/68/EU • Kvalitet ISO 9001 • Miljø ISO 14001 Sikkerhetsventil(er) benyttet skal være CE merket...
  • Page 6: Installasjonsinstruks

    3. INSTALLASJONSINSTRUKS 3.1 Produkter omfattet av denne instruksen 800 0302 Delta Geocoil - DGC 200 800 0304 Delta Geocoil - DGC 300 60 70 3.2 Medfølgende i leveransen °C Ref no. Antall Beskrivelse Varmtvannsbereder m/innebygget coil Termometer Termostat Varmeelement Følerlomme...
  • Page 7: Krav Til Installasjonssted

    3.3.2 Inntransport Produktet skal transporteres varsomt som illus- trert, med emballasje. Benytt håndtakene i esken. FORSIKTIG Stusser, ventiler og lignende skal ikke benyttes til å løfte produktet da dette kan forårsake funk- sjonsfeil. 3.4 Krav til installasjonssted og plassering FORSIKTIG Produktet skal plasseres i rom med sluk, utført iht.
  • Page 8: Rør-Installasjon

    3.5 Rør-installasjon Produktet er beregnet å være permanent tilkoblet hovedvanntilførsel. Ved installasjon skal godkjente rør av korrekt dimensjon be- nyttes. Gjeldende standarder og forskrifter skal følges. 60 70 °C 3.5.1 Anslutninger - dimensjon og funksjon Anslut- Dimensjon Funksjon ning 3/4” innv. gj. Kaldtvann inn. 3/4”...
  • Page 9 3.5.4 Montasjeinstruks ADVARSEL Produktet skal være fylt med vann før strøm tilkobles. Evt. overløpsrør fra sikkerhetsventiler skal være i egnet dimensjon og legges uavstengbart, brutt og frostfritt m/ fall til sluk. FORSIKTIG Produktet skal plasseres i rom med sluk, utført iht. våtromsnormen / siste TEK. Alternativt skal aut.
  • Page 10: El-Installasjon

    3.6 El-installasjon Fast el. montasje skal benyttes ved installasjon i A) Blå ledning (R) – Nøytral – er koblet til punkt nye boliger eller ved endring av eksisterende el. «A» på termostat. opplegg iht. forskrift. Nettkabel med støpsel for B) Brun ledning (S) – Faseleder – er koblet til veggkontakt kan benyttes ved utskiftning av punkt «B»...
  • Page 11 3.6.4 Montasjeinstruks ADVARSEL Produktet skal være fylt med vann før strøm tilkobles. Fast el. montasje skal benyttes ved installasjon i nye boliger eller ved endring av eksisterende el. opplegg iht. forskrift. Nettkabel med støpsel for veggkontakt kan benyttes ved utskiftning av produkt uten endring av el.
  • Page 12: Igangsettelse Første Gang

    4. IGANGSETTELSE FØRSTE GANG 4.1 Fylling av vann Sjekk først at alle røranslutninger er korrekt utført. retur-rør til coil av. Coilen tømmes via nedre Gjør deretter følgende: anslutning. NB: Coilen har et oppløft (O) fra A) Åpne en varmtvannskran – la denne stå åpen nederste punkt, hvor væske vil samles opp.
  • Page 13: Brukerveiledning

    5. BRUKERVEILEDNING 5.1 Innstillinger 5.1.1 Termostatinnstilling ADVARSEL Produktets termostat er stillbar fra 5-70°C. Termo- staten bør ikke stilles lavere enn 65°C for å unngå Kontinuerlig spenning er tilstede i el.-boksen. Før bakterievekst. For å justere temperaturen: elektrisk arbeid utføres skal strømtilførsel brytes A) Koble fra strømtilførselen.
  • Page 14: Feilsøking

    (se produktets merkeplate) len. Dersom problemet ikke er vist i feilsøkings- eller OSO Hotwater AS - se pkt. 7.2. FEILSØKING Problem Mulig feilårsak Mulig løsning...
  • Page 15: Garantibetingelser

    7. GARANTIBETINGELSER 1. Omfang OSO Hotwater AS (heretter kalt OSO) garanterer at Produktet jevnlig bruk, og at vannkvaliteten er iht. følgende: i en periode på 5 år fra kjøpsdato er; i) produsert i henhold - Klorider < 75 mg / L* til OSO spesifikasjoner, ii) fri for material og fabrikasjonsfeil, - Konduktivitet (EC) ved 25°C...
  • Page 17 O&M INFORMATION INSTALLATION MANUAL TDS - TECHNICAL DATA SHEET Manufactured by OSO Hotwater AS Industriveien 1 - 3300 Hokksund - Norway Tel: + 47 32 25 00 00 / Fax: + 47 32 25 00 90 E-mail: oso@oso.no / www.osohotwater.com...
  • Page 18 CONTENTS 1. Safety instructions ..........3 General information ........3 1.2 Safety instructions for users ..... 4 1.3 Safety instructions for installers ..... 4 2. Product description ..........5 2.1. Product identification ........5 2.2. Intended use ........... 5 2.3 CE marking ............5 2.4 Technical data ..........
  • Page 19: Safety Instructions

    1. SAFETY INSTRUCTIONS 1.1 General information • Read the following safety instructions carefully before installing, maintaining or adjusting the water heater. 60 70 • Personal injury or material damage may °C result if the product is not installed or used in the intended manner. •...
  • Page 20: Safety Instructions For Users

    1.2 Safety instructions for users WARNING Safety valve overflows must NOT be sealed or plugged (safety valve not included). The product must NOT be covered over the cover on the front. The product must NOT be modified or changed from its original state. Children must NOT play with the product or go near it without supervision.
  • Page 21: Product Description

    • Safety standard EN 60335-2-21 mation. • Welding standard EN ISO 3834-2 The product complies with Directives for: OSO Hotwater AS is certified for • Low voltage LVD 2014/35/EU • Quality ISO 9001 • Electromagnetic compatibility EMC 2014/30/EU •...
  • Page 22: Installation Instructions

    3. INSTALLATION INSTRUCTIONS 3.1 Products covered by these instructions 800 0302 Delta Geocoil - DGC 200 800 0304 Delta Geocoil - DGC 300 60 70 3.2 Included in delivery °C Num- Ref no. Description ber of Hot water heater with built-in coil...
  • Page 23: Requirements For Installation Location

    3.3.2 Delivery The product should be transported carefully as shown, with packaging. Use the handles in the box. CAUTION Pipe stubs, valves etc. should not be used to lift the product as this could cause malfunctions. 3.4 Requirements for installation location and positioning CAUTION The product should be placed in a room with a drain, in accordance with the wetroom...
  • Page 24: Pipe Installation

    3.5 Pipe installation The product is designed to be permanently connected to the mains water supply. Ap- proved pipes of the correct size should be used for installation. The relevant standards and reg- ulations must be followed. 60 70 °C 3.5.1 Connections - dimensions and function Connect- Dimension...
  • Page 25 3.5.4 Fitting instructions WARNING The product should be filled with water before the power is switched on. Any overflow pipe from safety valves must be of a suitable size, clear, undamaged and frost- free with a fall to the drain. CAUTION The product should be placed in a room with a drain, in accordance with the wetroom standard / latest TEK.
  • Page 26: Electrical Installation

    3.6 Electrical installation Fixed electric fittings should be used for installa- A) Blue wire (R) – Neutral – connected to point tion in new homes or when changing an existing ‘A’ on the thermostat. electrical setup in accordance with regulations. A B) Brown wire (S) –...
  • Page 27 3.6.4 Fitting instructions WARNING The product should be filled with water before the power is switched on. Fixed electric fittings should be used for installation in new homes or when changing an existing electrical setup in accordance with regulations. A mains cable with plug for wall socket can be used when replacing the product without changing the electrical setup.
  • Page 28: Initial Commissioning

    4. INITIAL COMMISSIONING 4.1 Filling with water First check that all pipes are connected correctly. tied via the lower connection. NB: The coil has Then proceed as follows: a riser (O) from the lowest point, where liquid is A) Open a hot tap – leave it open collected.
  • Page 29: User Guide

    5. USER GUIDE 5.1 Settings 5.1.1 Thermostat setting WARNING The thermostat on the product is adjustable from 5-70°C. The thermostat should not be set lower Constant voltage present in the junction box. Be- than 65°C to prevent bacteria growth. To adjust fore any electrical work is done, the power supply the temperature: must be disconnected and secured against acti-...
  • Page 30: Troubleshooting

    If tact the installer (see type plate on the product) the problem is not shown in the troubleshoot- or OSO Hotwater AS - see section 7.2. TROUBLESHOOTING Problem Possible cause of fault...
  • Page 31: Warranty Conditions

    7. WARRANTY CONDITIONS 1. Scope OSO Hotwater AS (hereinafter called OSO) warrants for 2 years should not be aggressive, i.e. the water chemistry shall from the date of purchase, that the Product will: i) conform to comply with the following:...
  • Page 32 OSO Hotwater AS Industriveien 1 3300 Hokksund - Norway Tel: + 47 32 25 00 00 oso@oso.no www.osohotwater.com © Alle deler av denne montasjeanvisningen er beskyttet av åndsverksloven og skal ikke reproduseres eller distribueres uten skriftlig avtale med produsenten. Forandringer forbeholdes.

Table of Contents