Bradford White Brute Mini BJVS User Information

Bradford White Brute Mini BJVS User Information

Residential gas-fired hydronic boilers

Advertisement

Quick Links

User's Information

WARNING:

Manual not followed exactly, a fire or explosion
may result causing property damage, personal
injury or death.
Do not store or use gasoline or other flammable
vapors and liquids in the vicinity of this or any
other appliance.

WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any
phone in your building.
• Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
• If you cannot reach your gas supplier, call the fire
department.
Installation and service must be performed by
a qualified installer, service agency, or the gas
supplier.

A. System Start Up

1.
Verify that the pump system is operating
properly.
a.
Shut off the manual gas valve.
b.
Set the wall thermostat to a setting high
enough to call for heat.
c.
The pump should come on immediately. If
it doesn't, have a service technician test the
electrical circuits.
If this Users Information
User's Information for
B
M
rute
Residential
Gas-Fired
Hydronic Boilers
Model BJVS
Vent damper is optional in some provinces of Canada..
AVERTISSEMENT:
tion utilisateurs manuel n'a pas suivi exactement,
un incendie ou une explosion peut entraîner des
dommages matériels, des blessures ou la mort
Ne pas entreposer ni utiliser d'essence ni d'autres
vapeurs ou liquides inflammables dans le voisinage
de cet appareil ou de tout autre appareil.
QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareils.
• Ne touchez à aucun interrupteur. Ne pas vous servir
des téléphones dans le bâtiment où vous vous
trouvez.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incendies.
L'installation et l'entretien doivent être assurés par un
installateur ou un service d'entretien qualifié ou par le
fournisseur de gaz.
2.
Light the pilot.
a.
The BJVS boiler does not require manual
lighting. The pilot is controlled by the
automatic ignition system.
b.
Different models of the JV boiler utilize
various gas valves. Although the gas valves
may have different control knobs, they are
all similar in operation. The gas valve has a
two-position knob - On and Off.
ini
Sizes 50-225
U.S. Patent No. 1,609,692
Canada Patent No. 383,318
Si cette informa-
1262X

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Brute Mini BJVS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Bradford White Brute Mini BJVS

  • Page 1 User's Information 1262X User's Information for rute Residential Gas-Fired Hydronic Boilers Sizes 50-225 Model BJVS U.S. Patent No. 1,609,692 Canada Patent No. 383,318 Vent damper is optional in some provinces of Canada.. WARNING: AVERTISSEMENT: If this Users Information Si cette informa- Manual not followed exactly, a fire or explosion tion utilisateurs manuel n'a pas suivi exactement, may result causing property damage, personal...
  • Page 2: Circulator Pump

    Page 2 RADFORD HITE Gas Control Knob Figure 1 - Gas Control for Automatic Ignition System Important: When lighting or relighting, wait the En cas de surchauffe ou si l'admission de gas full 5 minutes specified in the lighting instructions. ne peut être coupée, ne pas couper ni débrancher Unburned gases can accumulate in the fire box and l'alimentation électrique de la pompe.
  • Page 3 Page 3 rute NOTE: After installation and first start-up, check the heat exchanger for fouling after the following periods of operation: 24 hours 30 days 7 days 90 days+ Then once every six months thereafter. in Section 8D of the Installation and Operating Figure 4 - Pilot Arrangements 1) Pilot Instructions (Document number 1254) to ensure...
  • Page 4 10. Re-install the burner cover and tighten it in place. LOCKING SCREW (5/16" HEAD) AIR SHUTTER BURNER Figure 5 - Removing the Air Shutter Locking Screw 200 Lafayette St. www.BradfordWhite.com Middleville, MI 49333 Warranty: (800) 531-2111 Litho in U.S.A. © Bradford White 1509 Document 1262X-BW...

Table of Contents