Power Cord And Circuit Locator Operation; Connecting Vacuum And Solution Hose - Edic ENDEAVOR Owner's/Operator's Manual

Multi-purpose extractor
Hide thumbs Also See for ENDEAVOR:
Table of Contents

Advertisement

CONNECTING THE POWER CORDS:
The ENDEAVOR uses POWERCON twist lock connec-
tors on the end of the GFCI powercords. These mate to
the female receptacles on the body of the ENDEAVOR.
The female receptacles are found on the bottom right
hand side of the machine on the rear. See #12 on page 6.
To connect:
1. Take a powercon twist lock connector end and match
the chuck on the connector to the keyway on the
female chassis receptacle.
2. Insert the connector and turn in a clockwise
motion. A click will be heard when the con-
nector has engaged and is locked in place.
3. To disconnect, pull back on the sliding lock release
then turn the connector in a counter-clockwise mo-
tion. Pull the connector out of the chassis receptacle.
4. Connect each male wall plug to an individual circuit.
5. Press the RESET button on the cord's GFCI box.
When the red confirmation light on the GFCI box
turns on, the machine is ready to use. For more
information on the GFCI and its function, see pages
4 and 5.
USING THE CIRCUIT LOCATOR:
The ENDEAVOR has a built in circuit locator. When
the unit is plugged into two separate circuits, the circuit
locator confirmation light will turn on. The confirmation
light is marked "CT" and is located on the control panel.
See #3 on page 7.
1. Connect both power cords into machine.
2. Plug both male wall plug cord ends into two separate
wall plugs.
3. Press the reset button on each GFCI plug.
4. The light marked "CT" will turn on if you are on two
confirmed circuits. If you are in a very brightly lit
environment, shield the "CT" light with your hands
to better see the confirmation light.
5. If the "CT" light does not come on, try plugging into
another circuit until you get a confirmation light.
NOTE: Do not ignore the circuit locator. Do not run
both cords on one circuit. Doing so may overload the
circuits and trip the circuit breaker.
CONNECTING SOLUTION AND VACUUM
HOSES:
Hose connections for the solution line and the vacuum
line can both be found on the front of the machine in the
control panel. The control panel is #4 on page 6.
Solution hose: Connect the Q.D. on your solution hose
to the Q.D. on the machine's control panel (#6 on page
7). Connect opposite end of the solution hose to your
accessory.
Vacuum hose: Connect the cuff on your vacuum hose to
the vacuum hose barb on the machine's control panel (#7
on page 7). Connect opposite end of the vacuum hose
to your accessory. Make sure hose cuffs are pushed in
securely.
8

Advertisement

Table of Contents
loading

Table of Contents