4. Guide the other hose end to a suitable drain or sufficiently
dimensioned collection container. Please note that the
hose must not be kinked.
Disassemble the hose again when no longer operating the
device continuously. Allow hose and hose adapter to dry prior to
storage.
Setting the timer
For the device to switch on or off automatically after a
predefined number of hours (max. 24 hrs) you can programme
the timer. It is possible for the switch-on time and the switch-off
time to be activated at the same time, if so, both LEDs (18 and
19) will be illuminated.
The timer can be programmed in increments of 0.5 hours (0 to
10 h) or in increments of 1 hour (10 to 24 h).
Note:
Do not leave the operating device unattended in a freely
accessible room with an activated timer.
1. Press the TIMER button (23) to activate the timer.
ð The Off LED (18) is illuminated.
ð The display indicates the number of hours until
automatic switch-off (default: 0.0).
2. Press the selection button (22) to choose the number of
hours until automatic switch-off.
3. Alternatively, press the TIMER button (23) again to
programme automatic switch-on.
ð The On LED (19) is illuminated.
ð The display indicates the number of hours until
automatic switch-on (default: 0.0).
EN
4. Press the selection button (22) until the desired number of
hours until automatic switch-on has been set.
ð The number of hours is indicated on the display for
approx. 5 s. Then the current humidity level of the room
will be indicated.
5. It keeps running until the given switch-off time has expired
or until the device is switched off manually.
ð The device switches off or on after the predefined time.
ð The corresponding LED (Off for automatic switch-off or On
for automatic switch-on) is illuminated.
Note:
You can deactivate automatic switch-on and switch-off by
setting the respective number of hours back to 0.
When P2 is indicated on the display, the timer is also
deactivated.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. The compressor switches off and the fan
keeps running until defrosting is completed.
The duration of the defrost process can vary. Do not switch off
the device during automatic defrost. Do not remove the mains
plug from the mains socket.
Memory function
In case of brief power failures the device memorizes the
programmed nominal value for humidity. The pre-programmed
start and stop times for automatic operation are not saved.
Auto stop function
If the water tank is full, not inserted correctly or the set humidity
level has been reached, the device stops automatically.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
1. Press the POWER button (21).
2. Remove the mains plug from the mains socket.
3. If necessary, remove the condensation drain hose and any
residual fluid from it.
4. Empty the condensation tank, if need be.
5. Clean the device, and especially the air filter, according to
the chapter Maintenance.
6. Store the device according to the Storage chapter.