Errors and faults

The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
Note:
Wait for at least 3 minutes after maintenance and repair work.
Only then switch the device back on.
The device does not start:
• Check the power connection.
• Check the mains plug for damages.
• Check the condensation tank for correct seating. Check the
filling level of the condensation tank and empty it, if
necessary. The indicator light must not light up.
• Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is running, but no condensate forms:
• Check the float in the condensation tank for dirt. If
necessary, clean the condensation tank. The float must be
able to move freely.
• Check the room temperature. Observe the device's
permissible operating range according to the technical
data.
• Check the air filter for dirt. If necessary, clean or replace
the air filter.
• From the outside, check the condenser for dirt (see
chapter Maintenance). If your condenser is dirty, have it
cleaned by a specialist company or by Trotec.
The device is loud or vibrates; condensate is leaking:
• Check whether the device is standing upright and on an
even surface.
The device gets very warm, is loud or loses power:
• Check the air inlets and air filter for dirt. Remove external
dirt.
• From the outside, check the device for dirt (see chapter
Maintenance). If the inside of the device is dirty, have it
cleaned by a specialist company or by Trotec.
Your device still does not operate correctly after these
checks?
Have the device repaired by authorised expert staff or by Trotec.
9
Error codes
The following error codes can be displayed:
Error code Cause
AS
Error humidity sensor Disconnect the device
ES
Error at the
temperature sensor
of the evaporator
P2
Condensation tank
full or not inserted
correctly
EC
Leakage in the
refrigerant circuit
E3
General fault at the
device
dehumidifier TTK 96 E / TTK 127 E
Remedy
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.
Empty the condensation
tank or check the
condensation tank for
correct fit.
Switch the device off and
contact the customer
service.
Also see the information
regarding the refrigerant
circuit in chapter
Maintenance.
Disconnect the device
briefly from the mains.
Should the error still be
displayed after the restart,
please contact the
customer service.