Power Supply Units; Thermal Design - Dell PowerEdge R920 Technical Manual

A compute-intensive rack server designed to run mission-critical applications for midsized and large enterprises
Hide thumbs Also See for PowerEdge R920:
Table of Contents

Advertisement

Feature
Active power management
Fresh Air cooling
Rack infrastructure
Power supply units
Energy Smart power supplies have intelligent features, such as the ability to dynamically optimize 
efficiency while maintaining availability and redundancy. Also featured are  enhanced
power‐consumption reduction technologies, such as high‐efficiency power conversion and 
advanced thermal‐management techniques, and embedded power‐management features, 
including high‐accuracy power monitoring.
There are four power supply units available for the PowerEdge R920: which have auto 
sensing and auto switching  capability: 
750W AC  Platinum
750W AC  Titanium
1100W AC Platinum
1100W DC
 
Thermal design 
The thermal design of the PowerEdge R920 reflects the following:
Multiple sensors are monitored for thermal feedback control : The PowerEdge R920 
dynamically controls system cooling fan speed based on responses from all component 
temperature sensors, including processors, hard disk drives, DIMMs, storage cards and the 
inlet ambient temperature. Thermal management adjusts cooling according to what    the
25 |
Dell PowerEdge Technical Guide
 
Description
Intel Node Manager is an embedded technology that provides individual 
server‐level power reporting and power limiting functionality. Dell offers a 
complete power management solution comprised of Intel Node Manager 
accessed through Dell iDRAC7 Enterprise and OpenManage Power Center 
that allows policy‐based management of power and thermals at the 
individual server, rack and data center level.
Hot spare reduces power consumption of redundant power supplies. 
Thermal control of fan speed optimizes the thermal settings for your 
environment to reduce fan consumption and lower system   power
consumption.
 
Idle power enables Dell servers to run as efficiently when idle as when at full 
workload.
 
With the thermal design and reliability of Dell products, certain 
configurations have the capability to operate at excursion‐based 
temperatures beyond the industry standard of 35°C (95°F) up to 45°C (113°F) 
for excursionary periods of time and up to a 26°C dew point at 90% relative 
humidity; without impacting your availability model. Find additional 
information at Dell.com/FreshAir.
Dell offers some of the industry's highest‐efficiency power infrastructure 
solutions, including:
Power distribution units
Uninterruptible power supplies
Energy Smart containment rack   enclosures
Find additional information at content.dell.com/us/en/enterprise/
power‐and‐cooling‐technologies‐components‐rack‐infrastructure.aspx.
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents