Alarm - International Datacasting STAR Generation 2 User Manual

Receiver for audio networks
Table of Contents

Advertisement

Alarm

The following settings are available in the ALARM submenus:
MODE
: OFF
: Warning Only
: Warning+RelayA
: Warning+RelayB
: Warning+RelayC
S T A R
G e n
=
Warning and Alarm are switched off.
Upon an error condition the Warning light on the front
will be activated.
Upon an error condition, after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay A will
become active.
Upon an error condition, after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay B will
become active.
Upon an error condition after the warning delay period
has passed, the Warning light on the front panel will
illuminate. It will remain illuminated until the alarm delay
period has passed, at which point the Warning LED will
turn off, the Alarm Led will flash red and relay C will
become active.
2
R e c e i v e r
U s e r ' s
G u i d e
Page 19 of 47