Download Print this page

Newport PHAMP-3 Operator's Manual

Ph preamplifier with automatic temperature compensation

Advertisement

Quick Links

Warranty
All Products from NEWPORT ELECTRONICS, INC. are warranted
against defective material and workmanship for a period of one (1)
year from the date of delivery.
If the unit should malfunction, it must be returned to the factory for
evaluation. NEWPORT's Customer Service Department will issue an
Authorized Return (AR) number immediately upon phone or written
request. Upon examination by Newport, if the unit is found to be
defective it will be repaired or replaced at no charge. However, this
WARRANTY is VOID if the unit shows evidence of having been
tampered with or shows evidence of being damaged as a result of
excessive corrosion; or current, heat, moisture or vibration; improper
specification; misapplication; misuse or other operating conditions
outside of NEWPORT's control. Components which wear or which are
damaged by misuse are not warranted. These include contact points,
fuses, and triacs.
In addition to NEWPORT's standard warranty period, NEWPORT
ELECTRONICS will extend the warranty period for one (1) additional
year only if the warranty card enclosed with each instrument is
returned to NEWPORT.
Newport is glad to offer suggestions on the use of its various
products. Nevertheless, NEWPORT warrants only that the parts
manufactured by it will be as specified and free of defects.
NEWPORT MAKES NO OTHER WARRANTIES OR REPRESENT-
ACTIONS OF ANY KIND WHATSOEVER, EXPRESSED OR
IMPLIED, EXCEPT THAT OF TITLE, AND ALL IMPLIED
WARRANTIES INCLUDING ANY WARRANTY OF
MERCHANTABILITY AND FITNESS FOR A PARTICULAR
PURPOSE ARE HEREBY DISCLAIMED. LIMITATION OF
LIABILITY: The remedies of purchaser set forth herein are
exclusive and the total liability of NEWPORT with respect to this
order, whether based on contract, warranty, negligence,
indemnification, strict liability or otherwise, shall not exceed the
purchase price of the component upon which liability is based. In
no event shall NEWPORT be liable for consequential, incidental
or special damages.
Every precaution for accuracy has been taken in the preparation of
this manual; however, NEWPORT neither assumes responsibility for
any omissions or errors that may appear nor assumes liability for any
damages that result from the use of the products in accordance with
the information contained in the manual.
SPECIAL CONDITIONS: Should this equipment be used in any
nuclear installation or activity, purchaser will indemnify NEWPORT
and hold NEWPORT harmless from any liability or damage
whatsoever arising out of the use of the equipment in such a manner.
Return Requests
Direct all warranty and repair requests/inquiries to the NEWPORT
Customer Service Department. BEFORE RETURNING ANY
PRODUCTS(S) TO NEWPORT, PURCHASER MUST OBTAIN AN
AUTHORIZED RETURN (AR) NUMBER FROM NEWPORT'S
CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID
PROCESSING DELAYS). The assigned AR number should then be
marked on the outside of the return package and on any
correspondence.
The purchaser is responsible for shipping charges, freight, insurance
and proper packaging to prevent breakage in transit. NEWPORT's
warranty does not apply to defects resulting from action of the buyer,
mishandling, improper interfacing, operation outside of design limits,
improper repair, or unauthorized modification.
FOR WARRANTY RETURNS,
FOR NON-WARRANTY
please have the following infor-
REPAIRS, consult NEWPORT
mation available BEFORE con-
for current repair charges. Have
tacting NEWPORT:
the following information avail-
1. P.O. number under which
able BEFORE contacting NEW-
the product was PUR-
PORT:
CHASED,
1. P.O. number to cover the
2. Model and serial number of
COST of the repair,
the product under warranty,
2. Model and serial number of
and
product, and
3. Repair instructions and/or
3. Repair instructions and/or
specific problems relative to
specific problems relative to
the product.
the product.
Additional products from
Newport Electronics
T
N
S
F
Q
HE
EW
TANDARD
OR
Clock/Timers
Recorders
Counters
Relative Humidity
Flow Sensors
RTDs
Frequency Meters
Soldering Iron
Multimeters
Testers
On/Off
Strain Gauge
Controllers
Meter
pH Controllers
Thermistors
pH Electrodes
Thermocouples
pH Pens
Thermowells
PID Controllers
Timers
Printers
Totalizers
Process Meters
Transmitters
Rate Meters
Voltmeters
Wire
In the USA and Canada: 800-NEWPORT
In Mexico 95-800-NEWPORT
Or call your local Newport Office.
This documentation may not be copied, photocopied,
reproduced, translated, or reduced to any electronic medium
or machine readable form, in whole or in part, without prior
written consent of NEWPORT ELECTRONICS, INC.
© 1995 Newport Electronics, Inc. All rights reserved.
This product may be covered by one or more
of the following patents:
United States Patents Des. 336,895; 5,274,577
France Brevet No. 91 12756
Spain 2039150
United Kingdom Patent No. 2248954
and other international patents pending
From the technical library of:
__________________________________________________________________
M2266/N/0895
PHAMP-3
Inc
,
.
pH Preamplifier
UALITY
With Automatic Temperature Compensation
Operator's Manual
Newport Electronics
Inc
,
.

Advertisement

loading

Summary of Contents for Newport PHAMP-3

  • Page 1 NEWPORT’s Customer Service Department will issue an Newport Electronics pH Preamplifier Authorized Return (AR) number immediately upon phone or written request. Upon examination by Newport, if the unit is found to be defective it will be repaired or replaced at no charge. However, this TANDARD UALITY...
  • Page 2: General Description

    +108.4 +118.3 +124.2 +128.2 +136.2 +144.1 +148.1 as the NEWPORT IDP) or the +54.19 +59.15 +62.13 +64.12 +68.09 +72.05 +74.03 optional PSU-12V power supply. The PHAMP-3 uses a l000 ohm RTD –54.19 –59.15 –62.13 –64.12 –68.09 –72.05 –74.03 sensor for automatic temperature –108.4 –118.3 –124.2 –128.2 –136.2...