Schéma De Câblage - Mr. Heater MHU 80 Operating Instructions And Owner's Manual

Compact unit heater
Table of Contents

Advertisement

Available languages

Available languages

MAXIMUM LOAD NOT TO EXCEED
1
20VA AT 24V,CLASS 2
(2) S47 USED IN
2
,
75
80
AND 125 ONLY
NOTE-
IF ANY WIRE IN THIS APPLIANCE IS REPLACED,
IF ANY WIRE IN THIS APPLIANCE IS REPLACED,
IT MUST BE REPLACED WITH WIRE OF LIKE
IT MUST BE REPLACED WITH WIRE OF LIKE
SIZE, RATING AND INSULATION THICKNESS.
SIZE, RATING AND INSULATION THICKNESS.
WARNING-
ELECTRIC SHOCK HAZARD CAN CAUSE INJURY
ELECTRIC SHOCK HAZARD CAN CAUSE INJURY
OR DEATH. UNIT MUST BE GROUNDED IN
OR DEATH. UNIT MUST BE GROUNDED IN
ACCORDANCE WITH NATIONAL AND LOCAL
ACCORDANCE WITH NATIONAL AND LOCAL
CODES.
CODES.
DISCONNECT ALL POWER
DISCONNECT ALL POWER
BEFORE SERVICING!
BEFORE SERVICING!
DESCRIPTION
KEY
COMPONENT
A3
CONTROL BOARD (PCB)
B3
MOTOR- CIRCULATION
B6
MOTOR-COMBUSTION AIR INDUCER
C4
CAPACITOR-BLOWER MOTOR 1
C5
CAPACITOR-IN DUCED DRAFT MOTOR
DL36
RELAY-DELAY(N/A TO THESE MODELS)
GV1
VALVE- GAS
S10
SWITCH - PRIMARY GAS
S18
SWITCH-COMB AIR BLWR
S47
SWITCH-FLAME ROLLOUT
T1
TRANSFORMER- CONTROL
BLACK
L
WHITE
N
G
CHASSIS
GROUND
L1
CONNECT CHASSIS
CONNECT CHASSIS
GROUND TO
GROUND TO
EARTH GROUND
EARTH GROUND
SCHÉMA DE CÂBLAGE
FLAME
FLAME
SENSOR
SENSOR
(1)S47
T1
BROWN
SPARK
SPARK
ELECTRODE
ELECTRODE
CMB
BLWR
ACC
ACC
C5
B6
CAPACITOR USED IN 125 ONLY
B3
EQUIPMENT
EQUIPMENT
GROUND
GROUND
Radiateur compact
24VAC
24VAC
HOT
HOT
FLAME
1 TO 6
P1 ON BOARD
BROWN
PRES. SW.
PRES. SW.
5
RETURN
RETURN
S18
RED
PRES. SW.
PRES. SW.
2
OUT
OUT
COM
(2)S47
ORANGE
HIGH LIMIT
HIGH LIMIT
1
SW. RETURN
SW. RETURN
2
S10
BLUE
HIGH LIMIT
HIGH LIMIT
6
SWITCH OUT
SWITCH OUT
BLUE
GAS VLV
GAS VLV
3
RETURN
RETURN
GV1
YELLOW
GAS VLV
GAS VLV
4
OUT
OUT
GND
A3
LINE VOLTAGE FIELD INSTALLED
A3
THERMOSTAT WIRING
C4
CAPACITOR USED IN 75, 80 AND 125 ONLY
DIAGRAMME EN ÉCHELLE
Fan
Ventilateur
White
Blanc
L1
Black
Noir
(HOT)
N
White
(NEUTRAL)
Blanc
Orange
Flame Rollout Switch
Flame Rollout Switch
Flamber le commutateur
Flamber le commutateur
de deploiement
de deploiement
Flame Sensor/
Flame Sensor/
Detecteur de
Detecteur de
Flame Rollout Switch
Flame Rollout Switch
renommee
renommee
Flamber le commutateur
Flamber le commutateur
de deploiement
de deploiement
Red/
Red/
Rouge
Rouge
Air Switch/
Air Switch/
lnterrupteur a air
lnterrupteur a air
55
Manuel de l'utilisateur et instructions d'opération
R
1
24 Vac POWER
G
OPTIONAL FAN CONTROL
W
HEAT 1
C
COMMON
Red
R
G
W
White
t Ü á í
C
OPTIONAL THERMOSTAT
INSTALLATION
IT IS RECOMMENDED TO USE
18AWG WIRE WHEN INSTALLING
THE THERMOSTAT . CONNECT
THERMOSTAT WIRING TO
TERMINALS 'R' AND 'W'
AS ILLUSTRATED ON THE
SCHEMATIC DIAGRAM.
NOTE: THERMOSTAT TERMINAL
CONNECTIONS ARE MOUNTED
ON THE BACK PANEL OF THE
HEATER.
EXTERNAL THERMOSTAT
TERMINAL STRIP WARNING: DO
NOT CONNECT LINE POWER TO
THE THERMOSTAT TERMINAL
STRIP.
Black
Noir
ACB COOL
ACB COOL
Combustion Blower
Combustion Blower
ACB HEAT
ACB HEAT
ACB LOW
ACB LOW
Soufflerie De Ventilateur
Soufflerie De Ventilateur
ACC
ACC
ACC
ACC
White
Black
HTG ACC
HTG ACC
Blanc
Noir
CWB BLWR
CWB BLWR
Black
L1
Noir
Transformer/
Transformer/
Transformateur
Transformateur
120V
Blue
24 VAC (HOT)
24 VAC (HOT)
24V
Bleu
FLAME SENSOR
FLAME SENSOR
PSW RTN
PSW RTN
PSW OUT
PSW OUT
HIL RTN
HIL RTN
HIL OUT
HIL OUT
SPK ELE
SPK ELE
White
White
VLV RTN
VLV RTN
Blanc
Blanc
VLV OUT
VLV OUT
Blue
GND
GND
Yellow
Yellow
Blue
Bleu
Jaune
Jaune
Bleu
EQUIPMENT
EQUIPMENT
Gas Valve /
Gas Valve /
GROUND
GROUND
Valve a gaz
Valve a gaz
lgniter / Contact
É
24 V POWER (R)
THERMOSTAT
MAN BLOWER (G)
MAN BLOWER (G)
HEAT 1 (W1)
HEAT 1 (W1)
GND PRO THER
GND PRO THER
24 V (COMM) (C)
24 V (COMM) (C)

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mhu 50Mhu 125

Table of Contents