Page 1
OPERATING INSTRUCTIONS AND OWNER’S MANUAL FORCED-AIR PROPANE CONSTRUCTION HEATER READ INSTRUCTIONS CAREFULLY: If the information in this manual is not followed exactly, a fire or explosion WARNING: may result causing property damage, personal injury or loss of life. 2017-CB www.mrheater.com 800-25 1-0001...
WARNING: WARNING: GENERAL HAZARD WARNING: THE STATE OF CALIFORNIA REQUIRES THE FOLLOWING WARNING: WARNING: WARNING: CARBON MONOXIDE CAN KILL SPECIFICATIONS CONTENTS Bottle Pressure, 20 psig (0.14 MPa) Force-Air Propane Construction Heater...
ODOR FADE WARNING WARNING Asphyxiation Hazard FUEL GAS ODOR LP gas and natural gas have man-made odorants added specifically for detection of fuel gas leaks. If a gas leak occurs you should be able to smell the fuel gas. Since Propane (LP) is heavier than air you should smell for the gas odor low to the floor.
Page 5
OPERATING INSTRUCTIONS SERVICING PREPARING FOR OPERATION SIZE AND CAPACITY OF PROPANE CYLINDERS Force-Air Propane Construction Heater...
Page 6
HOW MUCH HEAT DO I REQUIRE? Recommended Minimum Gauge for Cord Extensions Wire Gauge Chart A.W.G. Name Plate 120V Cord Length in Feet Amps. BTU’S PER HOUR REQUIRED Cubic feet Temperature Rise Required ( 400FAVT - WIRING CHART of space to be heated PART COLOR...
Page 7
Model #400FAVT PARTS LIST DESCRIPTION DESCRIPTION Force-Air Propane Construction Heater...
OPERATING INSTRUCTIONS AND OWNER’S MANUAL READ INSTRUCTIONS CAREFULLY: WARNING: PARTS ORDERING INFORMATION: PURCHASING: FOR INFORMATION REGARDING SERVICE LIMITED WARRANTY ANSI Z83.7b/CSA2.14b-2009...
Page 9
GUIDE D’UTILISATION ET MANUEL DU PROPRIÉTAIRE APPAREIL DE CHAUFFAGE AU PROPANE À AIR PULSÉ POUR CHANTIER DE CONSTRUCTION LISEZ SOIGNEUSEMENT LES INSTRUCTIONS : Le fait de ne pas respecter les instructions données dans le présent guide avec AVERTISSEMENT : exactitude risque d’entraîner une explosion ou un incendie causant des dommages matériels, des blessures et des pertes de vie.
AVERTISSEMENT : AVERTISSEMENT : AVERTISSEMENT GÉNÉRAL DE DANGER : L’ÉTAT DE CALIFORNIE EXIGE QUE L’AVERTISSEMENT SUIVANT SOIT FOURNI : AVERTISSEMENT : AVERTISSEMENT : LE MONOXYDE DE CARBONE PEUT TUER TABLE DES MATIÈRES SPÉCIFICATIONS ° Pression de la bonbonne, 0,14 MPa (20 lb/po 1 16 °...
PRÉCAUTIONS LIÉES AU PRÉCAUTIONS LIÉES À LA SÉCURITÉ FONCTIONNEMENT n’orientez pas IMPORTANT : Figure 1 Figure 2 Figure 2 Figure 1 400 FAVT Force-Air Propane Construction Heater...
AVERTISSEMENT LIÉ AUX SUBSTANCES ODORANTES AVERTISSEMENT Risque d’asphyxie ODEUR DU GAZ COMBUSTIBLE Des additifs odorants ont été ajoutés au gaz propane liquéfié et au gaz naturel dans le but de faciliter la détection de fuites. Vous devriez remarquer une odeur de gaz combustible s’il y a une fuite.
INSTRUCTIONS DE FONCTIONNEMENT AVANT LE FONCTIONNEMENT DÉMARRAGE DIMENSIONS ET CONTENANCES DES ARRÊT BONBONNES DE GAZ PROPANE º º REDÉMARRAGE APRÈS UN ARRÊT D’URGENCE ENTRETIEN ET ENTREPOSAGE ENTRETIEN Force-Air Propane Construction Heater...
Page 14
DE QUELLE QUANTITÉ DE CHALEUR AI-JE Calibre minimum recommandé BESOIN ? pour rallonges Tableau de calibre de câble AWG Plaque Longueur de la rallonge en pieds d’identification 7,6 m 15,2 m 30,5 m 46 m 120 V A (25 ft) (50 ft) (100 ft) (150 ft)
Page 15
Modèle #400FAVT LISTE DES PIÈCES DESCRIPTION DESCRIPTION Force-Air Propane Construction Heater...
GUIDE D’UTILISATION ET MANUEL DU PROPRIÉTAIRE LISEZ SOIGNEUSEMENT LES INSTRUCTIONS : AVERTISSEMENT : INFORMATIONS SUR LA COMMANDE DE PIÈCES : ACHATS : POUR OBTENIR DES INFORMATIONS SUR LE SERVICE GARANTIE LIMITÉE ® ® ANSI Z83.7b/CSA2.14b-2009...
INSTRUCCIONES DE USO Y MANUAL DEL USUARIO CALENTADOR DE PROPANO A AIRE FORZADO PARA CONSTRUCCIÓN LEA CUIDADOSAMENTE LAS INSTRUCCIONES: Si no se siguen al pie de la letra las instrucciones de este manual, ADVERTENCIA: podría producirse un incendio o una explosión que provocaría daños materiales, lesiones o muertes.
ADVERTENCIA: ADVERTENCIA: ADVERTENCIA GENERAL DE PELIGRO: EL ESTADO DE CALIFORNIA EXIGE LA SIGUIENTE ADVERTENCIA: ADVERTENCIA: ADVERTENCIA: EL MONOXIDO DE CARBONO PUEDE MATAR ESPECIFICACIONES CONTENIDOS ° presión del cilindro, 0,14 MPa (20 lb/po 1 16 ° ° ° ° ° Force-Air Propane Construction Heater...
PRECAUCIONES DE UTILIZACIÓN PRECAUCIONES DE SEGURIDAD IMPORTANTE: Figura 1 Figura 2 Figura 2 Figura 1 400 FAVT Force-Air Propane Construction Heater...
ADVERTENCIA DE DISIPACIÓN DEL OLOR ADVERTENCIA Peligro de asfixia OLOR A GAS COMBUSTIBLE Los gases LP y el gas natural contienen sustancias aromáticas artificiales añadidas específicamente para facilitar la detección de fugas de gas. Si se produjera una fuga de gas, usted debe poder oler el gas combustible.
INSTRUCCIONES DE USO REPARACIÓN PREPARATIVOS PARA EL USO ENCENDIDO APAGADO TAMAÑO Y CAPACIDAD DE LOS CILINDROS DE PROPANO ° ° REINICIO LUEGO DEL APAGADO DE SEGURIDAD MANTENIMIENTO Y ALMACENAMIENTO Force-Air Propane Construction Heater...
Page 22
¿CUÁNTO CALOR ES NECESARIO? Calibre mínimo recomendado para los cables de extensión Gráfico del calibre del cable CAE Nombre Longitud del cable en pies Placa 120 V 7,6 m 15,2 m 30,5 m 46 m Amperios (25 ft) (50 ft) (100 ft) (150 ft) BTU POR HORA NECESARIOS...
Page 23
Model #400FAVT PARTS LIST DESCRIPTION DESCRIPTION Force-Air Propane Construction Heater...
Page 24
INSTRUCCIONES DE USO Y MANUAL DEL USUARIO LEA CUIDADOSAMENTE LAS INSTRUCCIONES: ADVERTENCIA: INFORMACIÓN PARA ORDENAR REPUESTOS: COMPRAS: SI DESEA OBTENER INFORMACIÓN ACERCA DE REPARACIONES GARANTÍA LIMITADA ANSI Z83.7b/CSA2.14b-2009...
Need help?
Do you have a question about the MH400FAVT and is the answer not in the manual?
Questions and answers