Download Print this page
Mr. Heater HEATSTAR MHU100NGPALP Installation Instructions Manual
Mr. Heater HEATSTAR MHU100NGPALP Installation Instructions Manual

Mr. Heater HEATSTAR MHU100NGPALP Installation Instructions Manual

Sea level natural/lp gas conversion kits: for unit heater models:

Advertisement

Available languages

Available languages

Quick Links

MHU100NGPALP
MHU100NGPAL
MHU125NGPALP
MHU125NGPAL
MHU150NGPALP
MHU150NGPAL
MHU200NGPALP
MHU200NGPAL
MHU250NGPALP
MHU250NGPAL
MHU300NGPALP
MHU300NGPAL
MHU400NGPALP
MHU400NGPAL
This conversion kit shall be installed by a qualified service agency in accordance with the
manufacturer's instructions and all applicable codes and requirements of the authority having
jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or
production of carbon monoxide may result causing property damage, personal injury or loss
of life. The qualified service agency performing this work assumes responsibility for the proper
conversion of this appliance with this kit.
All field gas piping must be pressure/leak tested prior to operation. Never use an open flame to
test for leaks. Use a soap solution or equivalent for testing.
The gas supply shall be shut off prior to disconnecting the electrical power, before proceeding
with the conversion. Failure to do so could result in a fire or explosion.
INSTALLATION INSTRUCTIONS
SEA LEVEL NATURAL/LP GAS CONVERSION KITS:
FOR UNIT HEATER MODELS:
MHU100NGPSSP
MHU100NGPSS
MHU125NGPSSP
MHU125NGPSS
MHU150NGPSSP
MHU150NGPSS
MHU200NGPSSP
MHU200NGPSS
MHU250NGPSSP
MHU250NGPSS
MHU300NGPSSP
MHU300NGPSS
MHU400NGPSSP
MHU400NGPSS
PLEASE RETAIN MANUAL FOR FUTURE REFERENCE
HSU100NGPALP
HSU100NGPAL
HSU125NGPALP
HSU125NGPAL
HSU150NGPALP
HSU150NGPAL
HSU200NGPALP
HSU200NGPAL
HSU250NGPALP
HSU250NGPAL
HSU300NGPALP
HSU300NGPAL
HSU400NGPALP
HSU400NGPAL
WARNING:
HSU100NGPSSP
HSU100NGPSS
HSU125NGPSSP
HSU125NGPSS
HSU150NGPSSP
HSU150NGPSS
HSU200NGPSSP
HSU200NGPSS
HSU250NGPSSP
HSU250NGPSS
HSU300NGPSSP
HSU300NGPSS
HSU400NGPSSP
HSU400NGPSS
60471

Advertisement

loading

Summary of Contents for Mr. Heater HEATSTAR MHU100NGPALP

  • Page 1 INSTALLATION INSTRUCTIONS SEA LEVEL NATURAL/LP GAS CONVERSION KITS: FOR UNIT HEATER MODELS: MHU100NGPALP MHU100NGPSSP HSU100NGPALP HSU100NGPSSP MHU100NGPAL MHU100NGPSS HSU100NGPAL HSU100NGPSS MHU125NGPALP MHU125NGPSSP HSU125NGPALP HSU125NGPSSP MHU125NGPAL MHU125NGPSS HSU125NGPAL HSU125NGPSS MHU150NGPALP MHU150NGPSSP HSU150NGPALP HSU150NGPSSP MHU150NGPAL MHU150NGPSS HSU150NGPAL HSU150NGPSS MHU200NGPALP MHU200NGPSSP HSU200NGPALP HSU200NGPSSP MHU200NGPAL MHU200NGPSS HSU200NGPAL...
  • Page 2 Table 1 - Natural to Propane gas Conversion Kit Model MH/HSU100 MH/HSU125 MH/HSU150 MH/HSU200 MH/HSU250 MH/HSU300 MH/HSU400 BTU/HR Input* 100,00 125,000 150,000 200,000 250,000 300,000 400,000 Orifice Drill Size 1.65mm Orifice Qty in N.G. Manifold Pressure 10”/2.5 kPa (W.C./kPa) Pressure Switch No Change Required Part Number F163070...
  • Page 3: Operation

    Installation of Kit Verify that the ignitor and sensor are the same location and have not been damaged. See Figure 1. Read these instructions carefully. Failure to follow these 14. Connect the gas supply piping to the heater using two instructions can damage product or cause a hazardous wrenches (one wrench to tighten and the other to backup) condition.
  • Page 4 ENERCO GROUP, Inc, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001 © 2022, Mr. Heater/ Heatstar®, Inc All rights reserved...
  • Page 5 INSTRUCTIONS D’INSTALLATION ENSEMBLE DE CONVERSION GAZ NATUREL/ PROPANE AU NIVEAU DE LA MER: POUR LES MODÈLES D’AÉROTHERME: MHU100NGPALP MHU100NGPSSP HSU100NGPALP HSU100NGPSSP MHU100NGPAL MHU100NGPSS HSU100NGPAL HSU100NGPSS MHU125NGPALP MHU125NGPSSP HSU125NGPALP HSU125NGPSSP MHU125NGPAL MHU125NGPSS HSU125NGPAL HSU125NGPSS MHU150NGPALP MHU150NGPSSP HSU150NGPALP HSU150NGPSSP MHU150NGPAL MHU150NGPSS HSU150NGPAL HSU150NGPSS MHU200NGPALP MHU200NGPSSP...
  • Page 6 Tableau 1 - Trousse de conversion de produits naturels au propane Modèle MH/HSU100 MH/HSU125 MH/HSU150 MH/HSU200 MH/HSU250 MH/HSU300 MH/HSU400 BTU/HR Input* 100,00 125,000 150,000 200,000 250,000 300,000 400,000 Taille de Orifice 1.65mm # de Orifices NG Pression d’admission (po)/ 10”/2.5 kPa (kPa) Interrupteur de Aucun changement requis...
  • Page 7: Opération

    Installation de la trousse Vérifiez que l’allumeur et le capteur sont au même endroit et n’ont pas été endommagés. Voir la Figure 1. Lisez attentivement ces instructions. Le non-respect de ces 14. Raccorder la tuyauterie d’alimentation en gaz à l’appareil instructions peut endommager le produit ou causer une de chauffage à...
  • Page 8 ENERCO GROUP, Inc, 4560 W. 160TH ST., CLEVELAND, OHIO 44135 • 800-251-0001 © 2022, Mr. Heater/ Heatstar®, Inc All rights reserved...
  • Page 9 INSTRUCCIONES DE INSTALACIÓN JUEGOS DE CONVERSIÓN GAS NATURAL/LP A NIVEL DEL MAR: PARA MODELOS DE CALEFACTOR: MHU100NGPALP MHU100NGPSSP HSU100NGPALP HSU100NGPSSP MHU100NGPAL MHU100NGPSS HSU100NGPAL HSU100NGPSS MHU125NGPALP MHU125NGPSSP HSU125NGPALP HSU125NGPSSP MHU125NGPAL MHU125NGPSS HSU125NGPAL HSU125NGPSS MHU150NGPALP MHU150NGPSSP HSU150NGPALP HSU150NGPSSP MHU150NGPAL MHU150NGPSS HSU150NGPAL HSU150NGPSS MHU200NGPALP MHU200NGPSSP HSU200NGPALP...
  • Page 10 Tabla 1 - Juego de conversión de gas natural a propano Modelo MH/HSU100 MH/HSU125 MH/HSU150 MH/HSU200 MH/HSU250 MH/HSU300 MH/HSU400 BTU/h de 100.00 125.000 150.000 200.000 250.000 300.000 400.000 entrada* Tamaño del 1.65 mm orificio Cantidad de orificios en el juego Presión del colector de gas 10”...
  • Page 11 Instalación de juego 13. Vuelva a colocar las conexiones eléctricas a la válvula de gas. Verifique que el encendedor y el sensor estén en la Lea atentamente estas instrucciones. El incumplimiento de misma ubicación y que no se hayan dañado. Consulte la estas instrucciones puede dañar el producto o causar una Figura 1.