Siemens SITRANS LG270 Operating Instructions Manual page 65

Guided wave radarfoundation fieldbus coax probe, minus 196...plus 280 degrees c; minus 196 ... plus 450 degrees c
Table of Contents

Advertisement

400 bar
(5800 psig)
356 bar
(5160 psig)
Fig. 37: Process pressure - process temperature (version -196 ... +280 °C/-321 ... +536 °F)
1
Process temperature (depending on the seal material)
2
Process pressure
400 bar
(5800 psig)
380 bar
(5510 psig)
350 bar
(5070 psig)
320 bar
300 bar
(4640 psig)
(4350 psig)
200 bar
(2900 psig)
100 bar
(1450 psig)
Fig. 38: Process pressure - process temperature (version -196 ... +450 °C/-321 ... +842 °F)
1
Process temperature (depending on the seal material)
2
Process pressure
Viscosity - dynamic
Vibration resistance
Ʋ Coax probe
PBD-51041071
380 bar
(5510 psig)
200 bar
(2900 psig)
100 bar
(1450 psig)
-196°C
-100°C
(-321°F)
(-148°F)
2
-196°C
-100°C
0°C
(-321°F)
(-148°F)
(32°F)
Flanges of 904L (1.4539): see ASME B16.5-2013, Table
2-3.11, permissible temperature range: -60 ... +400 °C
(-76 ... 752 °F)
0.1 ... 500 mPa s (requirement: with density 1)
1 g with 5 ... 200 Hz according EN 60068-2-6 (vibration
at resonance) with tube length 50 cm (19.69 in)
SITRANS LG270 - Operating Instructions
2
0°C
100°C
200°C
(32°F)
(212°F)
(392°F)
100°C
200°C
(212°F)
(392°F)
1
280°C
(536°F)
1
300°C
400°C
450°C
(572°F)
(752°F)
(842°F)
65