Advertisement

5 Configuration
5.2.3

Quick wizard: Options

External domestic hot water pump
#
Code
[A.2.2.A]
[D-02]
Domestic hot water pump:
▪ 0 (No): NOT installed
▪ 1 (Secondary rtrn): Installed for instant
hot water
▪ 2
disinfection
▪ 3 (Circul. Pump): Installed for tank
preheating.
▪ 4 (CP & disinf. Sh): Combination of 2
and 3.
See also illustrations below.
Domestic hot water pump installed for...
Instant hot water
h
b
c
a
f
g
a
Outdoor unit
b
Tank
c
Domestic hot water pump
d
Heater element
e
Non‑return valve
f
Shower
g
Cold water
h
Control box
Remote outdoor sensor
#
Code
[A.2.2.B]
[C-08]
External sensor (outdoor):
▪ 0 (No): NOT installed.
▪ 1 (Outdoor sensor): Remote outdoor
sensor, connected to the outdoor unit.
▪ 2 (Room sensor): Remote indoor
sensor, connected to option box
EK2CB07CAV3.
INFORMATION
You can only connect either the remote indoor sensor or
the remote outdoor sensor.
Control box EKCB07CAV3
#
Code
[A.2.2.E.1]
[E‑03]
Backup heater steps:
▪ 0 (default)
▪ 1
▪ 2
[A.2.2.E.2]
[5-0D]
BUH type:
▪ 1 (1P,(1/1+2)): 6  kW 1~  230  V
(default)
▪ 4 (3PN,(1/2)): 6 kW 3N~ 400 V (*9W)
▪ 5 (3PN,(1/1+2)): 9  kW 3N~  400  V
(*9W)
Installation manual
16
Description
(Disinf.
shunt):
Installed
Disinfection
h
b
c
a
d
e
Description
Description
The system allows for the connection of 2 types of backup heater
kits:
▪ EKMBUHCA3V3: 1~ 230 V - 3 kW backup heater
▪ EKMBUHCA9W1: Unified backup heater
Backup heater EKMBUHCA3V3 can only be configured to be a 3V3
backup heater. Unified backup heater EKMBUHCA9W1 can be
configured in 4 ways:
▪ 3V3: 1~ 230 V, 1 step of 3 kW
▪ 6V3: 1~ 230 V, 1st step = 3 kW, 2nd step = 3+3 kW
for
▪ 6W1: 3N~ 400 V, 1st step = 3 kW, 2nd step = 3+3 kW
▪ 9W1: 3N~ 400 V, 1st step = 3 kW, 2nd step = 3+6 kW
To configure the backup heater (both EKMBUHCA3V3 and
EKMBUHCA9W1), combine settings [E‑03] and [5‑0D]:
Backup heater
configuration
3V3
6V3
6W1
9W1
#
Code
[A.2.2.E.4]
[E-05]
f
g
N/A
[E-07]
[A.2.2.E.5]
[C-05]
[A.2.2.E.6]
[C-06]
[E-03]
[5-0D]
1
1 (1P,(1/1+2))
2
1 (1P,(1/1+2))
2
4 (3PN,(1/2))
2
5 (3PN,(1/1+2))
Description
DHW operation:
Can the system prepare domestic hot
water?
▪ 0 (No): NOT installed
▪ 1 (Yes): Installed
DHW tank type:
▪ 0 (EKHWS): DHW tank with booster
heater installed at the side of the
tank. (Default).
▪ 1 (EKHWP): DHW tank with booster
heater installed at the top of the tank.
External room thermostat for the main
zone:
▪ 1 (Thermo ON/OFF): When the used
external
room
thermostat
heat pump convector can only send a
thermo
ON/OFF
condition.
separation
between
cooling demand.
▪ 2 (H/C request): When the used
external room thermostat can send a
separate heating/cooling thermo ON/
OFF condition.
If there are two zones (main
+additional), then only Thermo ON/OFF
is possible.
External room thermostat for the
additional zone:
▪ 0: N/A
▪ 1 (Thermo ON/OFF): When the used
external
room
thermostat
heat pump convector can only send a
thermo
ON/OFF
condition.
separation
between
cooling demand.
▪ 2: N/A
If there are two zones (main
+additional), then only Thermo ON/OFF
is possible.
EBLQ+EDLQ011~016CAV3+W1
Daikin Altherma low temperature monobloc
4P522031-1 – 2018.01
or
No
heating
or
or
No
heating
or