Installation Recommendation - FCW DYNA POWER 503CV Operating Manual

Dyna power series
Table of Contents

Advertisement

2.0

INSTALLATION RECOMMENDATION

Installation Environment
DYNA POWER is designed for use in hazardous environments.
Examples of environments with increased hazardous environments are -
In locations in which freedom of movement is restricted, so that the operator is forced to perform the work
in a cramped (kneeling, sitting or lying) position with physical contact with conductive parts; In locations which
are fully or partially limited by conductive elements, and in which there is a high risk of unavoidable or
accidental contact by the operator, or in wet or damp hot locations where humidity or perspiration
considerable reduces the skin resistance of the human body and the insulation properties of accessories.
Environments with hazardous environments do not include places where electrically conductive parts in
the near vicinity of the operator, which can cause increased hazard, have been insulated.
Installation Location
Be sure to locate the welder according to the following guidelines:
l
In areas, free from moisture and dust.
l
In areas, free from oil, steam and corrosive
gases.
l
In areas, not exposed to direct sunlight or rain.
l
Ambient temperature: between -10 degrees C
to 40 degrees C.
WARNING
FCW advises that this equipment be electrically connected by a qualified electrician.
The following Primary Current recommendations are required to obtain the maximum welding current and
duty cycle from this Power Supply:
Model
DYNA POWER 350CV
DYN A POWER 503CV
DYNA POWER 500CV
DYNA POWER 630CV
DYNA POWER 630HCV
Table 1 primary current circuit sizes to achieve maximum current
DYNA POWER 350CV、503CV、500CV、630CV、630HCV Operating Manual
Primary
Minimum primary current
supply lead
size
2
Minimum 6.0mm
2
Minimum 8.0mm
2
Minimum 8.0mm
2
Minimum 10.0mm
2
Minimum 10.0mm
l
In areas, not subjected to abnormal vibration or
shock.
l
Place at a distance of 304.79mm or more from
walls or similar that could restrict natural airflow
for cooling.
circuit size
380V/ 22A
415V/ 20.1A
380V/ 38.5A
415V/ 35.3A
380V/ 38.5A
415V/ 35.3A
380V/ 62.5A
415V/ 57.2A
380V/ 62.5A
415V/ 57.2A
- 7 -
Current & Duty Cycle
350A/ 31.5V@60%
320A/ 30V@100%
500A/ 39V@40%
450A/ 36.5V@60%
400A/ 34V@100%
500A/ 39V@60%
450A/ 36.5V@100%
630A/ 44V@60%
500A/ 39V@100%
630A/ 44V@100%