Specifications; Duty Cycle - FCW DYNA POWER 503CV Operating Manual

Dyna power series
Table of Contents

Advertisement

2.02

Specifications

MODEL
Input voltage and
frequency and
380/415V 3ph
phases
KVA @ max output
Max current
Output current range
Open circuit voltage
Duty cycle at 40℃
Weight
Dimensions
550×300×490
2.03

Duty cycle

The duty cycle of a welding power source is the percentage of a ten (10) minute period that it can be
operated at a given output without causing overheating and damage to the unit. If the welding amperes
decrease, the duty cycle increases. If the welding amperes are increased beyond the rated output, the duty
cycle will decrease.
WARNING: Exceeding the duty cycle ratings will cause the thermal overload
protection circuit to become energized and shut down the output until has
cooled to normal operating temperature
NOTICE:
Due to variations that can occur in manufacture products, claimed performance, voltages, ratings, all
capacities, measurements, dimensions and weights quoted are approximate only. Achievable capacities and
ratings in use and operation will depend upon correct installation, use, applications, maintenance and
service.
DYNA POWER 350CV、503CV、500CV、630CV、630HCV Operating Manual
POWER
POWER
350CV
503CV
380/415V 3ph
25.3KW
14.5KW
500A
350A
30~500A
30~350A
78/85V
78/85V
40%
60%
55Kg
52.5Kg
550×300×490
Continually exceeding the duty cycle ratings
can cause damage to the welding power source.
POWER
500CV
380/415V 3ph
25.3KW
500A
30~500A
78/85V
60%
70Kg
560×365×640
Table 3
- 9 -
POWER
POWER
630CV
630HCV
380/415V 3ph
380/415V 3ph
41KW
630A
30~630A
30~630A
78/85V
78/85V
60%
85Kg
560×365×640
560×365×880
41KW
630A
100%
85Kg

Advertisement

Table of Contents
loading