Page 1
(Solax Power Co,. Ltd) Copyright Declaration The copyright of this manual belongs to Solax Power Network Technology(Zhe jiang) Co,. Ltd. (SolaX Power Co.,Ltd.). Any corporation or individual should not plagiarize, partitially or fully copy (including software,etc.), and no reproduction or distribution of it in any form or by any means. All rights reserved.
Contents Contents 1 Notes on this manual 1.1 Scope of Validity 1.2 Target Group 1.3 Symbols Used 2 Safety 2.1 Appropriate Usage 2.2 Important Safety Instructions 2.3 Explanation of Symbols 2.4 CE Directives 3 Introduction 3.1 Basic Features 3.2 Terminal of PV Inverter 3.3 Dimensions 4 Technical Data 4.1 DC Input...
X3-36.0-T-D 7.1 Trouble Shooting X3-30.0-T-D 7.2 Routine Maintenance X3-36.0-T-N X3-30.0-T-N 8 Decommissioning Note: “30.0” means 30kW. ”T” means “double” MPPT string. “D” means with “DC Switch”, ”N” means without “DC Switch”. 8.1 Dismantling The Inverter Store this manual where it will be accessible at all times.
2 Safety 2 Safety excessive stress include a surge arrester in case of a building with external lightning protection system(LPS) when separation distance is kept. To protect the d.c. system, surge suppression device(SPD type2) should be tted 2.1 Appropriate Usage at the inverter end of the d.c cabling and at the array, located between the The X3 Series is a PV inverter which converts the DC current of a PV inverter and the PV generator, if the voltage protection level(VP) of the surge...
Note ! Meaning of the light Symbol Light color Grounding the PV generator. Comply with the local requirements for grounding the PV Blue The inverter is in normal state. modules and the PV generator. SolaX recommends connecting the generator frame and other electrically conductive surfaces There are some problems, in a manner which ensures continuous conduction and ground Yellow...
PE Connection and leakage current CAUTION-RISK of electric shock from energy stored in capacitor, never work The end-use application shall monitoring of the protective conductor by on the solar inverter coupler, the MAINS cable, PV cables or the PV residual current operated protective device(RCD)with rated fault current generator when power is applied.
3 Introduction DC Switch(optional) DC Connector area 3.1 Basic Features Cables Opening for RS485 connection Congratulations on your purchase of a X3 Series inverter from SolaX. The X3 Pocket WiFi (Optional) inverter is one of the nest inverter on the market today, incorporating Waterproof Lock Valve state-of-the-art technology, high reliability, and convenient control features.
5 Installation 5 Installation 5 Installation X3 series inverter 5.1 Unpacking Bracket Warranty card User manual Quick installation guide Expansion tubes X3 Series User Manual 30KW/36KW Expansion screws Male DC connectors Female DC connectors Positive DC pin contact Negative DC pin contact AC terminal Earth terminal X3 Series 30KW/36KW...
5.3 Installation precaution The X3 series inverter is designed for outdoor installation(IP65). Make sure the installation site does not fall into none of the following conditions: Do not install the inverter in direct sunlight. Do not install the inverter on ?ammable constru tion material. Do not install the inverter in areas where highly ammable mateials are stored.
Loading capacity and hardness of the supporting surface, load rating of mounting bracket should be at least four times the weight of the devices according to IEC 62109-1 and supporting characteristic will be impaired by wear, corrosion, material fatigue or ageing. This should be calculated by inspection of the design data of supporting material and consulting construction engineer.
Page 12
X3-30.0-T-D/ X3-36.0-T-D/ Connection Steps X3-36.0-T-N X3-30.0-T-N a) Turn off the DC switch. 1000 Max. DC input voltage(V) b) Choose 12AWG wire to connect the PV module. c) Trip 6mm of insulation from the wire end. MPPT voltage range 480~800 580~850 (fullload)(V) 6.0 mm...
Page 13
For the terminal and cable design, please follow below requirement. Cable and Micro-breaker recommended X3-36.0-T-D/ Connection X3-30.0-T-D/ type X3-30.0-T-N X3-36.0-T-N ≥16mm Cable(Cu) (mm) Micro-breaker(A) table10 gure16 Insert striped cable into AC pin contact and insure all conductor strands Micro-breaker should be installed between inverter and grid, any loads are captured in the AC pin contact.
Page 14
Note 2:Fuses must be approved by Noti ed Body. 7:Screw down the screws on the terminal block. Connect the terminal Inverter is not provided galvanic isolation from the mains to the PV array, block. feedback current to the array is63A/250VACbased on the fuse provided in the mains.
Page 15
Communication LAN communication is one standard communication interface. It transmits the data between the router and X3 Series inverters in the local area network. User can set the parameters with specialized software provided by 1........12 SolaX. gure22 The pin de nition of the connector is as below: Definition 485_B 485_A...
Page 16
b. Dry contact(Optional) Dry contact is provided to give a remote monitor and remote control. The Make sure the directory is in accordance with above form remote monitor function provides an indication on the inverter’s working strictly! Do not modify the program le name ! Or it may status.
6 Internet monitoring function 5.7 Run the inverter 2.Please set static IPaddress:192.168.1.**(range:0~256), open the browser Start inverter after checking all below steps: a) Check that device is fixed well on the wall. (Chrome/Safari), input IP address: 192.168.1.13 (Please input the dynamic b) Make sure all the DC breakers and AC breakers are disconnected.
Page 20
7 Troubleshooting 7 Troubleshooting 7 Troubleshooting Current sensor fault 7.1 Trouble Shooting -DisconnectPV+andPV-,reconnectthe Current_Sensor_Fault -Or seek help form us, if can not go back to normal state This section contains information and procedures for solving problems with the X3 series inverters, and provides you with trouble shooting tips to identify and solve most problems that could occur with the X3 series EEPROM reading or writing fault EEPROM_WR_Fault...
Page 21
7 Troubleshooting 7 Troubleshooting When yellow light is on, the faults will be probability as below: 7.2 Routine Maintenance Inverters do not need any maintenance or correction in most condition, but FAN_Fault the cooling ?ns on the ear of house are covered by dirts if the inverter often loses power due to overheating.
Page 22
7 Troubleshooting 8 Decommissioning 8. Decommissioning 2: Check that if the indicators of the inverter are in normal state, check if the 8.1 Dismantling the Inverter keys of the inverter are in normal state, check if the display of the inverter is normal.
Need help?
Do you have a question about the X3-30.0-T-N and is the answer not in the manual?
Questions and answers