DIG LEIT Link Instruction Manual page 12

2-way radio remote control handset
Table of Contents

Advertisement

To select sensor location, press
or
and underscore MV/P or other, then press
Press
or
again to underscore OK. Press
screen specify which station number the sensor(s) is/are governed by.
NOTE: If MV/P is selected on the screen, sensor must connect to the master valve wire or
terminal. If other is selected, the sensor must be connected to one of the station's numbered
terminals.
This screen, Sensor Governs, allows you to designate,
which of the installed valves will be governed by the
sensor. To designate the valves that the sensor will control,
press
or
and underscore the valve numbers to be
governed by the sensor, then press
to select. Press
or
again to underscore OK. Press
NOTE: If an installed switch type sensor is triggered, any valve that is check marked and is
currently ON will complete its programmed run time. All further valve operations will be
prevented until the sensor deactivates and allows watering again.
The handset is trying to establish a link with a LEIT
controller. While the word Controller is blinking, wait for a
confirmation. If communication is established, the
following screens will confirm the changes. If
communication is not established the No Response-Try
Again screen will appear with Yes highlighted as the default. Press
communication with a LEIT controller that has the same ID, which uploads the new setting (if
revised).
If communication is established and only one screen has
changed, only one of these screens will show. If any other
changes have been made, all the changes will show in the
following screens. Press
to review the changes and
to exit.
Press
to repeat. Press
or
to move to the next feature.
UPLINK RADIO STATUS
The Uplink Radio Status is used for testing the range between the remote control handset and the
controller. The screen also provides the voltage information of the controller. The Rx and Tx figures
give an approximate indication of radio signal strength received at the controller (Rx) and handset
(Tx). The quality of the signal at that range is identified with a number between 0-3, with 3 being
the best, strongest signal. The V signal is an indication of the voltage level at the controller. The fully
charged controller will show 2.13 V on the display.
To enter Uplink Setup System press
. To skip Uplink
Radio Status and move to the next feature press
to continue.
The word Test will flash while attempting to establish a link
with a LEIT controller. If communication is not established
the No Response-Try Again screen will appear with Yes
highlighted as the default. Press
again to re-initiate
communication with a LEIT controller that has the same
controller ID.
to select.
to continue. If other was selected, in the next
Sensor
01 02
OK
Governs: 03 04
to continue.
Connect ID: 09
Controller:
OK
again to re-initiate
Changed Ctrl:09
Time/Date
OK
UPLINK
or
RADIO STATUS?
Rx Tx
V x5
Test? 0Yes 0No OK
19
If a link is established with a LEIT controller the quality of the radio signal and the controller power
strength can be checked.
Rx = Receive signal strength at controller from handset
with a minimum of 0 and maximum 3.
Tx = Transfer signal strength at handset from controller
with a minimum of 0 and maximum 3.
2.13 V = Controller voltage where 2.13 indicates that the controller is fully charged.
Press
to repeat. Press
or
to move to the next feature.
Rx2Tx2
2.13V x 5
Test? 0Yes 0No OK
20