STORZ & BICKEL Plenty Instructions For Use Manual

STORZ & BICKEL Plenty Instructions For Use Manual

Hide thumbs Also See for Plenty:

Advertisement

Quick Links

INSTRUCTIONS FOR USE
Read carefully before using the device
and save these instructions.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Plenty and is the answer not in the manual?

Questions and answers

Summary of Contents for STORZ & BICKEL Plenty

  • Page 1 INSTRUCTIONS FOR USE Read carefully before using the device and save these instructions.
  • Page 2: Table Of Contents

    I N S T R U C T I O N S F O R U S E E N G L I S H I N S T R U C T I O N S F O R U S E E N G L I S H Table of Contents Table of Contents ............
  • Page 3 1. P R O D U C T O V E R V I E W P L E N T Y 1. P R O D U C T O V E R V I E W P L E N T Y H O T A I R G E N E R AT O R VA P O R I Z AT I O N U N I T Vaporization Unit, comprising:...
  • Page 4: Explanation Of Symbols, Safety Recommendations

    You may download the current In- to IEC 60335-1, UL 499 und CAN/CSA 22.2 No. 64-M91. significant part of the Vaporizer and structions for Use for the PLENTY on must be provided to the user. www.storz-bickel.com. The instructions given in these In-...
  • Page 5: Safety Recommendations

    2 . S A F E T Y R E C O M M E N D AT I O N S , 2 . S A F E T Y R E C O M M E N D AT I O N S , E X P L A N AT I O N O F S Y M B O L S E X P L A N AT I O N O F S Y M B O L S 2.2.
  • Page 6: Intended Use

    2 . S A F E T Y R E C O M M E N D AT I O N S , 4 . O V E R V I E W O F P L A N T S E X P L A N AT I O N O F S Y M B O L S Below is an overview of the plants that WARNING:...
  • Page 7: Factors Influencing Vaporization

    5 . FA C T O R S I N F L U E N C I N G VA P O R I Z AT I O N 6 . T H E H O T A I R G E N E R AT O R P L E N T Y The amount of aromas and fragrances If no more vapor is produced at the 6.1.
  • Page 8: Storage

    6 . T H E H O T A I R G E N E R AT O R P L E N T Y 7. C O M M I S S I O N I N G A N D O P E R AT I O N 6.4.
  • Page 9: Heating Up

    7. C O M M I S S I O N I N G A N D O P E R AT I O N 7. C O M M I S S I O N I N G A N D O P E R AT I O N 7.1.
  • Page 10: Filling The Filling Chamber

    The Filling Chamber. thermometer measures the tempera- ture of the heat exchanger, and a cor- responding calibration displays the re- Standing up the PLENTY Hot Air Generator spective temperature in the Filling Chamber during inhalation.
  • Page 11 8 . F I L L I N G T H E F I L L I N G C H A M B E R 8 . F I L L I N G T H E F I L L I N G C H A M B E R correct wrong vapor...
  • Page 12 8 . F I L L I N G T H E F I L L I N G C H A M B E R 8 . F I L L I N G T H E F I L L I N G C H A M B E R This prevents the vaporization mate- rial from shifting even when the Filling Chamber is only partially filled, ena-...
  • Page 13: Application

    Hold your breath for a few sec- then begin. onds and then exhale slowly. It is advis- able to deliberately concentrate on Heating the PLENTY Hot Air Generator your breathing process. After vaporization, turn off the PLEN- T Y Hot Air Generator, unplug the power cord, and let it cool down before putting the device away.
  • Page 14: Disassembling, Cleaning And Assembling

    10. D I S A S S E M B L I N G , C L E A N I N G A N D A S S E M B L I N G 10.1. Disassembling and Reassem- PLENTY Vaporization Unit The Vaporization Unit may be eas- bling the PLENTY Vaporization ily disassembled and reassembled Please allow the Vaporization Unit to Unit for cleaning in a few seconds.
  • Page 15: Disassembling The Filling Chamber Cap

    10. D I S A S S E M B L I N G , C L E A N I N G A N D A S S E M B L I N G 10. D I S A S S E M B L I N G , C L E A N I N G A N D A S S E M B L I N G 10.3.
  • Page 16: Assembling The Filling Chamber

    11. A C C E S S O R I E S 11. A C C E S S O R I E S 11.1. Filling Chamber Reducer Filling the Filling Chamber Reducer 11.2. Dosing Capsules and Magazine Grind the plant material and fill the with aromatic Oils Dosing Capsule by using the Magazine Suitable for vaporizing small...
  • Page 17 11. A C C E S S O R I E S 11. A C C E S S O R I E S Attach the cap onto the Dosing Cap- Inserting the Dosing Capsules sule. Repeat the filling process until the First, the Filling Chamber Reducer, that desired amount of Dosing Capsules is is available as an accessory as well,...
  • Page 18: Technical Specifications

    Storz & Bickel GmbH & Co. KG hereby guarantee the customer that discretion whether to correct a defect the type label of the PLENTY Hot Air In Grubenäcker 5-9 the product will be free from defects in covered to warranty law through repair Generator.
  • Page 19: Copyright

    14. WARR ANT Y, LIABILIT Y such damages involve death, personal injury, or injury to health, or if the in- jury is related to a cardinal contractual obligation. In such cases, we will also be liable to the customer for simple negligence.
  • Page 20 S T O R Z & B I C K E L G M B H & C O. K G In Grubenäcker 5-9 · 78532 Tuttlingen/Germany...

Table of Contents