Do you have a question about the Crafty+ and is the answer not in the manual?
Questions and answers
Allan Kerr
January 25, 2025
How to reinstall mouthpiece after cleaning?Crafty Plus
1 comments:
Mr. Anderson
May 14, 2025
To reinstall the mouthpiece on the STORZ & BICKEL Crafty Plus after cleaning, follow these steps:
1. Ensure all parts are completely dry. 2. Reassemble the Cooling Unit by placing the cleaned or new screen, seal ring, and cap in their correct positions. 3. Attach the mouthpiece by aligning it with the Cooling Unit and pressing it into place until it fits securely.
Make sure all parts are undamaged and properly seated to ensure good airflow and function.
I N S T R U C T I O N S F O R U S E E N G L I S H Table of Contents ............page Product Overview CRAFTY + ..........5 Scope of Delivery............5 Functional Elements ............6 Service ................7 For your Safety ................9 Symbols ................8...
Page 3
I N S T R U C T I O N S F O R U S E E N G L I S H Table of Contents ............page Cleaning ..................18 Cooling Unit ..............18 7.1.1 Product Overview ..........18 7.1.2 Disassembling ..........18 7.1.3 Cleaning ............
Page 4
I N S T R U C T I O N S F O R U S E E N G L I S H Table of Contents ............page Dosing Capsules (for single Use) and Magazin ...27 9.3.1 Filling the Dosing Capsules ......27 9.3.2 Filling the Magazine with Dosing Capsules ........
1 P R O D U C T O V E R V I E W C R A F T Y + 1.2 Functional Elements 1 Filling Chamber 5 LED-Display 2 Mouthpiece 6 EON/OFF Switch 3 Filling Chamber Tool 7 Cooling Unit 4 USB-C Charging Socket (behind the Filling Chamber Tool)
1 P R O D U C T O V E R V I E W C R A F T Y + 1.3 Service Please check whether all components have been included. If not, please inform the Storz & Bickel Service Center. In the case of technical problems, questions about the device, warranty claims and disposal of the device, customers in the US and Canada should contact the following address:...
2 F O R Y O U R S A F E T Y 2.1 Symbols Bullet points Hazard symbol Operating instructions Note 2.2 Explanation of Signs Please follow these instructions carefully! Symbol for the manufacturer - the manufacturer‘s name and address are next to the symbol The device was introduced after 13 August 2005.
2 F O R Y O U R S A F E T Y Safety tested and production monitored by TUEV SUED according to EN 60335-1, UL 499 and CAN/CSA-22.2 No. 64-M91. Safety tested and production monitored by TUEV SUED according to EN 60335-1.
2 F O R Y O U R S A F E T Y 2.3 Basic Rules X Store and use the Vaporize and USB-C Cable only at a sufficient X These Instructions for Use are an distance from heat sources integral part of the Vaporizer and (oven, stove, fireplace, etc.) and...
2 F O R Y O U R S A F E T Y X Before switching on the Vaporizer, IMQ, VDE, +S, etc.) if the stated ensure that all vapors, e.g. from power value exceeds the power flammable cleaning agents and requirements (A=Ampere) of the disinfectants, have evaporated.
3 I N T E N D E D U S E The Vaporizer is used to produce fra- grances or aromas from the herbs and plant parts listed in Chapter 4. The scents and aromas are released by means of vaporization with hot air and can be inhaled directly.
5 FA C T O R S I N F L U E N C I N G VA P O R I Z AT I O N Please follow these instructions so You can repeat the vaporization pro- that you can adjust the Vaporizer with cess with the same contents of the the plant material you use to suit your filling chamber until vapor is no longer...
6 C O M M I S S I O N I N G A N D O P E R AT I O N Blue, slow-flashing light: the battery 6.1 Unpacking is between 61 and 96% charged. X Check the Vaporizer according to Blue, rapidly flashing light: the Chapter 1.1 “Scope of Delivery“, battery is between 31 and 60%...
6 C O M M I S S I O N I N G A N D O P E R AT I O N X Fill the filling chamber completely NOTICE with ground plant material up to the plastic edge. Loss of warranty / Excessively compressed...
6 C O M M I S S I O N I N G A N D O P E R AT I O N 6.5.2 Basic Temperature Superbooster mode ends automat- ically 90 seconds after the booster X Press the orange ON/OFF switch temperature has been reached;...
6 C O M M I S S I O N I N G A N D O P E R AT I O N The automatic switch off can be reset to two minutes by brief- CAUTION ly pressing the ON/OFF switch during operation.
7 C L E A N I N G 7.1 Cooling Unit 7.1.2 Disassembling Cooling Unit and Mouthpiece must A heated Cooling Unit is easier to be free of deposits. These are disassemble because the steam caused by steam condensate in- condensate can be sticky.
Page 19
7 C L E A N I N G X When cleaning the Cooling Unit Cap in isopropyl alcohol, remove the Cap Lock by pulling it up on one side. X Lever out the large Base Seal Ring The signet hologram on the cap with the Filling Chamber Tool at the lock is a sticker.
7 C L E A N I N G 7.1.3 Cleaning X Check all parts for damaged sur- faces, cracking, softening, harden- ing, soiling or discoloration. CAUTION X Remove any damaged parts. X If necessary, clean the cap lock Isopropyl alcohol is flammable with warm rinse water or wipe it and may easily ignite.
7 C L E A N I N G Disregarding this may allow plant X Using the Filling Chamber Tool, particles to enter the Cooling Unit, press the screen flat into the pro- so blocking this or be inhaled. vided groove. 7.2 Screens 7.4 Vaporizer and USB-C Cable X After each vaporization, clean the...
8 S T O R Z & B I C K E L A P P The Storz & Bickel App is not neces- X Make sure that the Bluetooth® sary for operating the Vaporizer, does function is switched on and that however allow individual settings to be it is not occupied by another made and allows the readout of additi-...
8 S T O R Z & B I C K E L A P P Information justed to the degree using the low- er plus and minus keys. The differ- Here you will find further information ence in degrees between booster such as the list of plants, the Quick and superbooster temperature is Start Manual, the Instructions for Use,...
8 S T O R Z & B I C K E L A P P 8.5 Further individual Settings 8.6 Reset to Default Settings Settings which you have changed via The Storz & Bickel App can be used to make other useful setting the Storz &...
Page 25
9 O P T I O N A L A C C E S S O R I E S Wear & Tear Set - SKU 06 02 CY The Wear & Tear Set contains all spare parts required to replace the Cooling Unit. Cooling Unit Set - SKU 03 05 CY / Cooling Unit - SKU 03 04 CY Replace the Cooling Unit regularly to ensure cleanliness.
9 O P T I O N A L A C C E S S O R I E S 9.1 Herb Mill Use the Filling Aid for easy and clean filling of the filling chamber. You can store ground plant mate- rial in the bowl of the Filling Aid.
9 O P T I O N A L A C C E S S O R I E S X Put the lower lid on the Filling Aid by turning it counterclockwise. X Put the Cooling Unit on the Vapor- izer by turning it 90°...
9 O P T I O N A L A C C E S S O R I E S X Fill the Dosing Capsules using the X Close the Magazine by turning the Magazine Lid. Magazine Lid clockwise. X Unscrew the Magazine Lid coun- terclockwise.
10 FA U LT S 10.1 Possible Faults / Troubleshooting Fault Possible Cause/Remedy Vaporizer cannot be Make sure that the battery is charged. switched on. LED display flashes Battery temperature is either too high or too low. alternately red/blue. Let the Vaporizer either cool down or warm up. LED display flashes blue.
11 T E C H N I C A L S P E C I F I C AT I O N S CRAFTY + Vaporizer: Supply voltage: 5 V DC The voltage specification can be found on the Vaporizer type plate: Power required by Vaporizer: 10 W max.
13 WA R R A N T Y, L I A B I L I T Y 13.1 Warranty Storz & Bickel will decide at its own discretion whether to correct a defect Storz & Bickel GmbH and Storz & covered by warranty law through re- Bickel America Inc., as the sellers, pair or by delivering a new product to...
13 WA R R A N T Y, L I A B I L I T Y lated to a cardinal contractual obligati- on. In such cases, we will also be liable to the customer for simple negligence. 13.3 Copyright This document is copyright protected, and may not be used either in whole or in part pursuant to Sections 15 et seqq.
Page 33
S T O R Z & B I C K E L G m b H In Grubenäcker 5-9 · 78532 Tuttlingen/Germany...
Need help?
Do you have a question about the Crafty+ and is the answer not in the manual?
Questions and answers
How to reinstall mouthpiece after cleaning?Crafty Plus
To reinstall the mouthpiece on the STORZ & BICKEL Crafty Plus after cleaning, follow these steps:
1. Ensure all parts are completely dry.
2. Reassemble the Cooling Unit by placing the cleaned or new screen, seal ring, and cap in their correct positions.
3. Attach the mouthpiece by aligning it with the Cooling Unit and pressing it into place until it fits securely.
Make sure all parts are undamaged and properly seated to ensure good airflow and function.
This answer is automatically generated